Marantz AV8003 ユーザーガイド

ページ / 92
CONNECTIONS
BASIC 
OPERA
TION
ADV
ANCED 
OPERA
TION
REMOTE 
CONTROLLER
TROUBLESHOOTING
OTHERS
NAMES AND 
FUNCTION
SETUP
27
ENGLISH
Note: 
• Less than 6 positions can be measured, but it is 
recommended to measure in all 6 positions in order 
to obtain the best results.
• The time needed to complete calculations depends 
on the number of connected speakers and measured 
listening positions. The more speakers and listening 
positions, the more time is needed.
 10.
  Checking Measurement Results 
 
  When calculations for the measurement results 
end, a screen appears for confirming the 
calculation results.
          C H E C K   R E S U L T
 
   
S P E A K E R S   C O N F I G
    S P E A K E R S   S I Z E
    D I S T A N C E
    C H A N N E L   L E V E L
    C R O S S O V E R   F R E Q
    S T O R E
                         
         
E X I T
 
  Select items to check with the 
3/4 cursor 
buttons and press the ENTER button to enter 
them.
Note: 
To check equalizer (MultEQ) parameters, see page 
37.
[Example]  Confi rmation screen for speaker detection
        S P E A K E R   C O N F I G
    C H E C K   ! !       S P E A K E R
F R O N T         :   Y E S
C E N T E R       :   N O N
F R O N T   R     :   Y E S
S U R R . R       :   Y E S
S U R R . B   R   :   N O N
S U R R . B   L   :   N O N
S U R R . L       :   Y E S
S U B   W         :   Y E S
R E T U R N              
N E X T
[Example]  Confi rmation screen for the distance from 
speakers to the listening position
              D I S T A N C E
U N I T               :      
m
F R O N T   L         :     3 . 0 5   m
C E N T E R           :     3 . 0 5   m
F R O N T   R         :     3 . 0 5   m
S U R R . R           :     3 . 0 5   m
S U R R . B   R       :     3 . 0 5   m
S U R R . B   L       :     3 . 0 5   m
S U R R . L           :     3 . 0 5   m
S U B   W             :     3 . 0 5   m
R E T U R N               N E X T
 
       
*  The units can be changed by moving the cursor to 
[ft] of UNIT and pressing 
1 / 2 the cursor buttons. 
Each time a 
1 / 2 cursor button is pressed, the units 
alternate between [ft] (feet) and [m] (meters).
Note:
Pressing “EXIT” prior to pressing “STORE” erases all 
measurement results and calculation results, therefore 
operate the remote controller with care.
When storing operations end, the following OSD 
appears on the display.
          2 . S P K R   S E T U P
 
A U T O   S E T U P
  M A N U A L   S E T U P
  T H X   A U D I O   S E T U P
R E T U R N              
         
E X I T
Notes:
• Do not turn the power to the unit off while storing 
parameters in memory. This may erase all data in the 
unit’s memory and may damage the unit.
• Please set any THX Certifi ed speakers manually to 
“Small” and the crossover “80 Hz” after Auto setup 
operation.
[Example]  Confi rmation screen for speaker size and 
crossover frequency
          S P E A K E R   S I Z E
F R O N T   L           :   A U T O
C E N T E R             :   A U T O
F R O N T   R           :   A U T O
S U R R . R             :   A U T O
S U R R . B   R         :   A U T O
S U R R . B   L         :   A U T O
S U R R . L             :   A U T O
R E T U R N              
N E X T
        C R O S S O V E R   F R E Q
F R O N T     :   A U T O      
C E N T E R   :   A U T O      
S U R R       :   A U T O      
S U R R . B   :   A U T O      
R E T U R N
*  AUTO is displayed to indicate that the speaker size 
and crossover frequency results were automatically 
measured.
 11.
  Storing Measurement Results in Memory
 
  Once finished confirming the measurement 
results, select “RETURN” with the 
3/4 cursor 
buttons and press the ENTER button to display 
the CHECK RESULT screen.
        C H A N N E L     L E V E L
F R O N T   L         :       0 . 0 d B
C E N T E R           :     - 6 . 5 d B
F R O N T   R         :     - 1 . 5 d B
S U R R . R           :     + 1 . 0 d B
S U R R . B   R       :     + 9 . 5 d B
S U R R . B   L       :   + 1 2 . 0 d B
S U R R . L           :     - 2 . 5 d B
S U B   W             :   - 1 2 . 5 d B
R E T U R N
              N E X T
 
          C H E C K   R E S U L T
 
    S P E A K E R S   C O N F I G
    S P E A K E R S   S I Z E
    D I S T A N C E
    C H A N N E L   L E V E L
    C R O S S O V E R   F R E Q
   
S T O R E
                         
         
E X I T
 
  Place the cursor on “STORE” and press 
the  ENTER button to store all parameters 
including the equalizer parameters in memory. 
If not wanting to store the calculation results in 
memory, place the cursor on “EXIT” and press 
the ENTER button.
AV8003N.indb   27
AV8003N.indb   27
08.4.28   10:49:17 AM
08.4.28   10:49:17 AM