 18
Setting functions and options
You can change options for a number of system functions. Available functions depend on 
the type of system you have. The functions, along with available options are described on 
pages 18–19.
This thermostat is pre-set for a single-stage heating/cooling system.  
Setting function 1 for a heat pump will adjust the default settings.
1  Press 
Fan
 and 
simultaneously and hold 
for approximately 3 seconds. The screen will 
change to display two numbers and the button 
designations will be 
DoneBack, blank, Next.
2  Press 
Next
 until you see the function number—
the larger number on the left—you want to set.
3  Change options for any function by pressing 
s
 
or 
until the correct option (smaller number on 
right) is displayed.
4  Repeat Steps 2 and 3 until you have set all 
functions that you wish to change.
5  When you have made all changes, press 
Done
 
to save and exit.
HOLD
MCR33883
MCR33884
HOLD
System setup
Function 
Settings & Options
1
Select System  
Type
If you are not sure  
of your heating/
cooling system 
type or have other 
questions, go to  
wifithermostat.com
Heat/cool: Gas, oil or electric heating with central air conditioning.
Heat pump: Heat pump without backup or auxiliary heat.
Heat only: Gas, oil or hot water heat without central air conditioning.
Heat only with fan: Gas, oil or electric heat without central air 
conditioning.
Cool only: Central air conditioning only.
Heat pump: Heat pump with backup or auxiliary heating.
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 
cooling stages (wires on 
Y and Y2).
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 
cooling stage (wire on 
Y).
Heat/Cool Multiple stages: 1 heat stage (wires on W), 2 cooling stages 
(wire on 
and Y2).
2
Heat Pump 
Changeover Valve 
(for heat pumps 
only)
Cooling changeover valve: Use this setting if you connected a wire 
labeled “O” to the O/B terminal.
Heating changeover valve: Use this setting if you connected a wire 
labeled “B” to the O/B terminal.
3
Heating Fan 
Control
Gas or oil heat: Use this setting if you have a gas or oil heating system 
(system controls fan operation).
Electric heat: Use this setting if you have an electric heating system 
(thermostat controls fan operation).
5
Heating Cycle  
Rate
Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
Electric furnace: Electric heating systems.
Hot water or high-efficiency furnace: Hot water system or gas furnace 
(more than 90% efficiency).
Gas/oil steam or gravity system: Steam or gravity heat systems.
6
Heating Cycle  
Rate Stage 2