INSTALLER SELF-TEST
Use the Installer Self-Test to check the thermostat oper-
ation. Refer to Table 4 for a list of the available self-tests. 
CAUTION
Equipment Damage Hazard.  
Minimum compressor off-time is bypassed 
during Installer System Test.
Avoid cycling compressor quickly.
To start the self-test:
Press and hold the increase ! and decrease " keys at 
the same time until 10 appears. All segments of the 
display are displayed before the 10 appears. See Fig. 12 
and 13.
Fig. 12. Display of all LCD segments.
Fig. 13. Display of test number.
Refer to Table 5 for the directions and results of the 
specific tests.
NOTE: Press Time 
  to advance to the next test and 
Time 
 to go back to the previous test. Press 
Run Program to exit the self-test.
NOTE: Press any key and the displayed numbers 
change. Press Time 
∇ 
to go to the previous test 
and Time 
 to go to the next test. The Run    
Program key does not exit this test. Press   
Time 
or Time 
 and then the Run Program key 
to exit.
Table 4. Tests Available In The Installer Self-Test.
Test 
Number
System Test Description
10-19
Heating equipment can be turned on and off
30-39
Cooling equipment can be turned on and off
40-49
Fan equipment can be turned on and off
60 0 to 
60 19
Keyboard keys test
70-79
Thermostat information including date code 
and software versions are displayed
M14559
Aux Ht
Set Day/Time
Set Program
Mon
Wake Leave Return
Sleep
Outdoor
Room
Filter
Wait
FFan
Em Heat
On
Auto
Off
Cool
Auto
AM
PM
Hold for
Heat Cool
Repl Batt
Recovery
DST
Tue Wed Thu Fri Sat Sun
Days
Temporary Setting
Em Ht
M14612
Table 5. Installer Self-Test Options.
Key to 
Press
Test 
Number
Description
Heating Equipment System Test
Time 
10
Enter heating equipment system test
 !
11
Heat comes on. When Installer Setup 
number 2 is 1, the system fan is also 
energized
"
10
Heat and system fan turn off
Cooling Equipment System Test
Time 
30
Change from heating to cooling 
equipment system test
 !
31
Cool and system fan come on
"
30
Cool and system fan turn off
Fan Equipment System Test
Time 
40
Change from cooling to fan 
equipment system test
 !
41
Fan comes on
"
40
Fan turns off
Key Equipment System Test
Time 
60
Change from fan to key operation 
system test