Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル

ページ / 383
 
OM Management Portal (OMP) 
 
157 
• 
Use common certificate configuration: Enables the use of the system-wide certificate validation 
settings, as configured on the 
System -> Provisioning -> Certificates page (see section 5.4.2.5). 
For further information on the user data import, see the OM DECT Phone Sharing and Provisioning 
Guide
.  
 
6.5.7.3 DECT phones synchronization 
The user data synchronization feature ensures that all user and device database information is 
distributed to all OMM instances in the system. Each peripheral OMM must have a connection to the AXI 
interface of the central OMM (and the standby central OMM, if configured) to send and receive updated 
user data information. Specify the same user credentials used to access the central OMM via the OMP. 
For more information on this feature, see section 7.16. 
 
• 
Activate synchronization: Enable user data synchronization for the OMM.  
• 
OMM1: Specifies the IP address of the central OMM.  
• 
OMM2: Specifies the IP address of a second central OMM, in the case of a standby configuration. 
• 
User name: Specifies the user name required to access the central OMM.  
• 
Password: Specifies the password required to access the central OMM.  
• 
Password confirmation: Confirms the password required to access the central OMM.  
 
6.5.7.4 Manual DB import 
The manual database import feature allows the import of an OMM database. 
Please note: 
A manual import of a database results in a reset of the OMM. 
 
For a description of the parameters on the 
Manual DB import tab, see the description of the System -> 
Data management page of the OMM Web service. The same parameters are described in the Manual 
Database Import section (section 5.4.7.1).