Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル

ページ / 383
 
Configuration and Administration 
 
313 
Precondition: A DECT phone must be assigned to the user (fixed, logged in). The DECT phone is 
subscribed and attached. Delivery of battery level is supported.
 
7.29.2.9  Software Status (SWS) 
The DECT phone software must provide the minimum of required features which could be controlled by 
the current OMM version. Therefore the appropriate minimum DECT phone software version is hard 
coded in the OMM and validated by user monitoring. The status will be set to “Warning” if the DECT 
phone software version is less than the hard coded value of the OMM. 
Delivery of the software version is supported only by Mitel 600 devices. 
Precondition: A DECT phone must be assigned to the user (fixed, logged in). The DECT phone is 
subscribed and attached.
 
7.29.3 ESCALATION 
If the OMM detects the unavailability of a user (marked as “unavailable”), this will be escalated only once 
by submitting a warning alarm trigger via OM AXI. 
If the OMM detects finally the unavailability of a user (marked as “unavailable/escalated”), this will be 
escalated only once by submitting an alarm trigger via OM AXI. 
The user must become available again before the unavailability of a user will be escalated the next time. 
 
7.29.4 ALARM TRIGGERS 
• 
The “UMON-WARNING-USERSTATE” alarm trigger is used to escalate the detection of the 
unavailability. 
• 
The alarm triggers “UMON-ERROR-USERSTATE” and “LOC-ERROR-USERSTATE” are used to 
escalate the final detection of the unavailability. 
• 
The “UMON-OK-USERSTATE” alarm trigger is sent by the OMM if a user becomes available again. 
These are static, predefined alarm triggers like “SOS” and “MANDOWN” which do not have a telephone 
number to call. 
The alarm triggers “UMON-WARN-USERSTATE”, “UMON-ERR-USERSTATE” and “LOCERR-
USERSTATE” provide information about the cause why the user became unavailable (one or more of 
status attribute IDs: HAS, HSS, HRS, HCS, SRS, SCS, CDS, …). 
 
7.29.5 OM LOCATING APPLICATION 
To be visible in the OM Locating application, the monitored user must be locatable. Tracking can be 
enabled. 
                                                
1
 The Mitel 600  DECT phone family provides battery status information if the DECT phones are updated 
to the current software version. 
2
 The Mitel 600  DECT phone family provides software version information if the DECT phones are 
updated to the current software version.