MEAN WELL PB-1000-12 Lead Acid Battery Charger, For V Batteries PB-1000-12 ユーザーズマニュアル

製品コード
PB-1000-12
ページ / 14
2
Assemb ly guideline s:
1.The ch arger should be turned OFF prior to battery connection. Suitable wire gauge
2. Af te r pl ugg ing i n t h e A C pow er c ab l e, f li ck t he ON/ OFF (0/ -) sw i tch t o t h e O N (-)
positio n. T he LED indicator on the switch will lig ht up.
should be chosen based on rated charging current of the charger unit. Double-check
battery polarity before making the battery connection. Positive terminal of the charger
must be co nnected to + of t he b atte ry and ne gative t erminal to of the batt ery. Also,
make sure the posit ive and neg at ive ter min als of the charger are not accidentall y
shorted together.
3.De rating c urve
3.1 Cha rging curren t VS temperature
AMBIENT TEMPERATURE (
)
20
40
60
80
100
-20
0
10
20
30
40
50
60
70 (HORI ZONTAL)
Figu re 2.2 Ba ck P anel
LED
Indi cator
Func tion
Connec t or
2/3/8 stag e
se lect io n s witc h
{
+
+
Battery A
Battery B
-
-
Sta ge 8/3/2
Please che ck batter y
polarity before
connection
WARNING :
Battery B
Positive
Battery A
Positive
Common
Negative
Pin No.
Function Description
1,2
RY13
Rela y con tact rating (max.): 3 0V/1A. "Short" when bank A is fu ll.
"Open" when ban k A is still charging .
4.Fu nction desc ription for CN100