MEAN WELL PB-1000-12 Lead Acid Battery Charger, For V Batteries PB-1000-12 ユーザーズマニュアル

製品コード
PB-1000-12
ページ / 14
3
Pin No.
Function Description
3,4
5,6
9,10
7,8
RY14
RY15
RC-/RC+
GND/RTH
Rela y con tact rating (max.): 3 0V/1A. "Short" when bank B is f ull.
Re lay conta ct ra ting (max.): 30V/1A. "Short" w hen the unit is work ing
Turn the output ON an d OFF by electrical or dr y c ontac t be tween
Temperature sensor which comes with the char ger ca n be conne cted
"Open" when ban k B is still cha rg ing .
prope rly. "Open" when th e u nit has faile d or prot ect io n has a ctiv ated.
pin10 (RC+) and pin9 (RC-). Open: start charging. Short: s top charging.
to the unit to allow temperature compensation of the charging v oltage.
If the temperature sen sor is not used , the charge r ca n sti ll w ork
norma lly.
5.LE D In dication
6.Ex planati on of operation logi c (charg ing stages) :
PB -10 00 h as a tot a l of 3 ch argi ng m ode s to cho ose from , 2 s t ag es, 3 sta ges , and
8 stages. 8 stages charging differ from 2 stages with the addit ion of pulse, soft start,
analysis, recondition, float, and mai ntain stages. 2 stages provide simple and quick
charging. 3 stages is sim ilar to 2 stages with the exception of not shutting OFF after
the battery is fully charged. Lastly, 8 stages will allow charging to maximum capacity.
User can select bet ween 2,3 or 8 stages depend ing on their requirement.
6.1 2 s tage charging (flick swi tch to "2" stage)
PB -1000 ha s ch annels A & B which can p erform 2 stages charging indi vidually.
Channel A will be the first to commence charging. During initial charge (stage 1),
charger will provide maximum current to the battery. The built-in fan will also tur n
ON . As t he batt ery s t art s t o get f ul l , cha rgin g cu rren t wi l l gra dua l ly d ecre ase
(stage 2). When charging current decrease to less than 10% of max. LED indicator
wi l l t ur n Gr e en t o s how a f u l l ch a rg e . C h an n el A wi l l t ur n OF F w hile cha rgi n g
com mence at Channel B. After the battery at channel B is fully charged, PB-1000
will turn OFF its outputs.
Start
B ank A
C onsta nt
C ur rent
Bank B
Cons tant
Curre nt
Bank A
Consta nt
Voltage
Bank B
Con stant
Volt age
Bank A
Charging
Ends
Ba nk B
Charging
En ds
Type s of failure:
1
5
2
3
4
Battery disconnected
Activation of protection function (e.g. OTP, OVP, and Short)
Damaged battery
Rever se polari ty
Incorrect battery voltage (e.g. PB-1000-12 connected to 24V battery)
Statu s
Co lor
Re d
Orang e
Green
Stea dy
Fail
Full
Charging
Charging
Flas hin g