Enable optimized network drivers
14
ParaStation5 Administrator's Guide
The  values  that  might  be  assigned  to  the  HWType  parameter  have  to  be  defined  within  the
parastation.conf
 configuration file. Have a brief look at the various Hardware sections of this file
in order to find out which hardware types are actually defined.
Other possible types are: 
mvapi
openib
gm
ipath
elan
dapl
.
To enable shared memory communication used within SMP nodes, no dedicated
hardware entry is required. Shared memory support is always enabled by default.
As there are no options for shared memory, no dedicated hardware section for this
kind of interconnect is provided.
4. Define Nodes
Furthermore ParaStation has to be told which nodes should be part of the cluster. The usual way of
using the Nodes parameter is the environment mode, that is already enabled in the template file.
The general syntax of the Nodes environment is one entry per line. Each entry has the form
  hostname id [HWType] [runJob] [starter] [accounter] 
This  will  register  the  node 
hostname
  to  the  ParaStation  system  with  the  ParaStation  ID 
id
.  The
ParaStation ID has to be an integer number between 0 and NrOfNodes-1.
For each cluster node defined within the Nodes environment at least the hostname of the node and
the ParaStation ID of this node have to be given. The optional parameters HWTyperunJobsstarter
and  accounter  may  be  ignored  for  now.  For  a  detailed  description  of  these  parameters  refer  to  the
parastation.conf(5) manual page.
Usually the nodes will be enlisted ordered by increasing ParaStation IDs, beginning with 0 for the first
node. If a front end node exists and furthermore should be integrated into the ParaStation system, it
usually should be configured with ID 0.
Within  an  Ethernet  cluster  the  mapping  between  hostnames  and  ParaStation  ID  is  completely
unrestricted.
5. More options
More configuration options may be set as described in the configuration file 
parastation.conf
. For
details refer to the parastation.conf(5) manual page.
If using 
vapi
 (HwType ib) or 
DAPL
 (HwType dapl) layers for communication, e.g.
for Infiniband or 10G Ethernet, the amount of lockable memory must be increased.
To do so, use the option 
rlimit memlock
 within the configuration file.
6. Copy configuration file to all other nodes
The modified configuration file must be copied to all other nodes of the cluster. E.g., use psh to do so.
Restart all ParaStation daemons.
In order to verify the configuration, the command
  # /opt/parastation/bin/test_config
could be run. This command will analyze the configuration file and report any configuration failures. After
finishing these steps, the configuration of ParaStation is done.
4.2. Enable optimized network drivers
As explained in the previous chapter, ParaStation5 comes with its own versions of adapted network drivers
for Intel (e1000) and Broadcom (bcm5700) NICs. If the optimized ParaStation protocol p4sock is used to