power cable must be inserted into a socket on the UPS. (See
 
refer to the UPS manual to determine the location of these sockets. The UPS must 
then be connected to main power. 
 
C.4.2  Set the Baud Rate 
The default baud rate for the COM 2 serial port is 38400 and must be changed to 
2400. 
For instructions on changing the baud rate, please refer to the SCSI to SATA 
RAID Subsystem’s Operation Manual that came with the subsystem.
 
 
C.4.3 Connect COM2 
The separately purchased audio
-
jack
 
to
 
DB9 serial cable connect
s
 the COM2 port on 
the controller module to the UPS directly. (See
 
Figure C-25) The cable transmit
s
 
UPS status updates to the controller module and will in turn determine the write 
policy of the controller module. To connect the serial communication cable to the 
subsystem controller, insert the audio jack connector on one end of the cable into the 
COM2 port on the controller module. To see how to connect the DB9 connector to 
the UPS, please refer to the documentation that came with your UPS. 
 
Figure C-25: Connecting the UPS to the Subsystem 
 
 
C.5   Power On 
When powering on the subsystem, the UPS must be powered on before the subsystem. 
For 
instruction on
 how to power on the UPS, please refer to the documentation that came with 
your UPS. Note that the power on sequence described in Chapter 4 will be altered. The power 
on sequence when a UPS is connected is shown below: 
Step 1. Power on SCSI 
c
hannel connection devices (including hubs and 
switches). 
Step 2. Power on the UPS. 
Step 3. Power on the subsystem. 
Step 4. Power on the host computers.