The DS.11 Configuration Utility 
 
 
 
3-17 
Station Control Tab 
The Station Control tab enables you to revert the unit parameters to their factory 
defaults, reset the unit and export the unit’s configuration to a configuration file. 
 
Figure 
 
3-10: The Station Control Tab 
The Station Control tab is comprised of the following components: 
♦  Station Control: Click the 
 button for all parameters to revert to the 
factory defaults. 
♦  Click the 
 button to export the current basic configuration of this unit 
to a file. A popup window is displayed prompting you to specify the name of the 
file. The created file can be used to save the configuration information or to 
send it to tech support as a reference for troubleshooting. 
♦  Reset Unit: Click the 
 button to reset the unit and apply 
any changes made to the system parameters.  
The flash memory can store two software versions. One version is called 
Current and the other is called Shadow. New software versions are loaded as 
the shadow version. You can select the shadow version as the new active 
version by selecting Reset and Boot from Shadow Version. However, after the 
next reset, the current version is re-activated. To continue using the currently 
active version after the next reset, select Use Current Version After Reset
The parameters configured in the unit are not changed as a result of loading 
new software versions unless the new version includes additional parameters 
or additional changes in the list of parameters. New parameters are loaded with 
their default values. 
♦  Click the 
 button to reset the unit and boot from the 
shadow version. 
♦  Click the 
 button to use the current running version after 
the next reset.