Maxon Telecom Modem MM-6280IND ユーザーズマニュアル

ページ / 60
 
 
HSDPA Standard At Commands        Page 13 of 60                             Version 1.2 
 
 
4800, 9600, 19200), (45, 50, 75, 110, 150, 300, 600, 38400, 
57600, 115200, 230400) 
+IPR=<value> Set value 
+ICF Opt. 
TE2-MT2 Character Framing. This extended-format 
compound parameter is used to determine the local serial 
port start-stop (asynchronous) character framing that the 
MT2 shall use while accepting TE2 command set and while 
transmitting information text and result codes to the TE2, if 
this is not automatically determined (see +IPR). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
+ICF? Shows current settings 
+ICF=? Shows supported range 
+ICF=<format_value,parity_value> sets value 
<format> 
valid numeric values 
auto detect [NOT SUPPORTED] 
1 8Data 
2Stop 
8Data 1Parity 1Stop 
3 8Data 
1Stop 
(Default) 
4 7Data 
2Stop 
7Data 1Parity 1Stop 
6 7Data 
1Stop 
<parity> 
defined numeric values 
0 odd 
1 even 
Mark [NOT SUPPORTED] 
3 space 
(Default) 
supported 
+IFC Opt. 
TE2-MT2 Local Flow Control. This extended-format 
compound parameter is used to control the operation of 
local flow control between the TE2 and MT2 
[1]
<c_by_t> Description 
0 None 
1 Xon/Xoff 
local 
DC1/DC3 on circuit 103; do not pass 
DC1/DC3 characters to the remote 
DCE. 
Circuit 133 (Ready for Receiving) 
(Default) 
supported