Chapter 5             
Subsystem Maintenance and Upgrading 
5.1  Overview 
5.1.1  
Maintenance 
Constant monitoring and maintenance of your SS16i subsystem will minimize subsystem 
downtime and preserve the working integrity of the system for a longer period of time. If any of 
the subsystem components fail, they must be replaced as soon as possible.  
 WARNING! 
Do not remove a failed component from the subsystem until you have a replacement 
on hand. If you remove a failed component without replacing it, the internal airflow 
will be disrupted and the system will overheat causing damage to the subsystem. 
All of the following components can be replaced in case of failure: 
1.  Controller module – Section 0 
2.  Memory module – Section 0 
3.  BBU module - Section 0 
4.  PSU modules – Section 5.5 
5.  Cooling fan modules (bundled with PSU modules, not separately available) – Section 0 
6.  Hard drives – Section 5.7 
 
5.1.2  General Notes on Component Replacement 
ƒ  With the exception of the RAID controller module, all of the components on the 
SS16i subsystem, including the PSU modules (along with the cooling modules 
within), and drive trays, are hot-swappable and can be replaced while the subsystem 
is still in operation. 
ƒ  Qualified engineers who are familiar with the SS16i subsystem should be the only 
ones who make component replacements. If you are not familiar with the subsystem 
and/or with RAID subsystem maintenance in general, it is strongly advised that you 
refer subsystem maintenance to a suitably qualified maintenance engineer.  
ƒ  Normalized airflow is directly dependent on the presence of all subsystem 
components. Even if a subsystem component fails, it should not be removed from the 
subsystem until a replacement is readily at hand and can be quickly installed. 
Removing a subsystem component without replacing it can lead to permanent 
subsystem damage.