Meridian Data 16i ユーザーズマニュアル

ページ / 91
Chapter 5: Subsystem Maintenance and Upgrading  
  
5-3 
5.2.2  Notes on Controller Module Maintenance 
ƒ  The controller module contains a DIMM module for cache buffer. When replacing the 
controller module, the DIMM module can be removed and used on the replacement 
controller if they are known to be good. 
ƒ  When replacing the controller module, you must remember that the controller board is 
one of the most sensitive components in the EMD SS16I subsystem. All previously 
stipulated safety precautions (see Chapter 2) must be strictly adhered to. Failure to 
adhere to these precautions can result in permanent damage, resulting in timely delays.  
ƒ  For your own safety and that of the subsystem, make sure that no power is being 
supplied to the system prior to replacing the controller module. 
 
5.2.3  Removing the Controller Module 
To remove the controller module: 
 Step 1.
 
Prepare a clean, static-free work pad or container into which to 
place the controller that will be removed from the chassis.  
 Step 2.
 
Make sure there is no data access to the subsystem to avoid losing 
data. Stop all I/O accesses to the subsystem and make sure all cached 
writes have been distributed to disk drives. 
 Step 3.
 
Power off the subsystem. If possible, power off the subsystem in the 
way described in Chapter 4. Be sure to flush all cached data before 
powering off the subsystem. If it is not possible to do this turn off 
both PSU modules and disconnect the power cords.  
 Step 4. 
Disconnect all cables that are connected to the controller module you 
wish to replace. These include the Ethernet cables connected to the 
network, and any cable connected to the RS-232C audio jack 
connector. 
 Step 5. 
Remove the BBU module if one has been installed. Loosen the BBU 
module’s retention screws and then retrieve it from the chassis.