Location Requirements
CLEARANCES
RATINGS
Select a location for the refrigeration unit that meets the 
requirements of the building plans, local codes, and 
personnel. The unit must be positioned for free airflow 
as well as for future service. The following requirements 
must be met:
100 GPH (379 LTR/hr) potable water supply 
Beverage quality CO
2
 gas (bulk or bottled supply) 
with a minimum 3/8" (.96 cm) line
One Bag-In-Box (BIB) (or Figal) container of each 
post mix syrup flavor.
NOTE: Refer to nameplate on side of refrigeration unit 
for voltage and amperage specifications. Make all 
electrical connections at the junction box located at the 
top rear of unit. Optional equipment may require 
additional power supplies.
NOTE: Potable water connections to the equipment 
must comply with local plumbing code requirements, 
particularly the back-flow prevention requirements.
KITCHEN EQUIPMENT INSTALLER 
REPRESENTATIVE RESPONSIBILITIES
Prior to scheduling Multiplex Equipment installer, 
the following steps listed below must be completed:
1. Usable floor sewer drain.
2. A 120 VAC, 3-wire, 1 Phase, 60 Hz Electrical Power 
Supply (minimum 30 Amp capacity).
-
International Models are 50 Hz
3. Usable potable water.
4. CO
2
 Gas (bulk or bottled supply); minimum 3/8" line.
5. One 5 gallon (19 L) container or Bag-In-Box 
container of each post mix syrup flavor.
6. A 120 VAC, 3-wire, 1 Phase, 60 Hz dual wall 
receptacle for optional electrical equipment 
(domestic only).
NOTE: Do not schedule the authorized Multiplex 
Equipment Installer until all of the above have been 
completed. It will only result in charge-backs to you for 
the unnecessary trips.
REQUIREMENTS FOR POST MIX UNITS
Conduit can be run through floor or ceiling chase.
60°F (15.6°C) minimum and 105°F (40.5°C) 
maximum operating ambient conditions.
For indoor installation only.
Syrup supply can be located on stand or adjacent to 
refrigeration unit.
Control Side (Right)
18" (45.7 cm)
Tower Connection Side (Left)
12" (30.5 cm)
Back Side
6" (15.2 cm)
Ceiling
18" (45.7 cm)
Model
Evaporator Rating
at 20°F (-6.5°C)
Heat Rejection (Max.)
Model 11M 
5,150 BTUH 
1,159 kcal/hr 
8,638 BTUH 
1,949 kcal/hr 
!
Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure
to a high concentration of CO
2
 gas causes tremors,
which are followed rapidly by loss of consciousness
and suffocation. If a CO
2
 gas leak is suspected,
particularly in a small area, immediately ventilate the
area before repairing the leak. CO
2
 lines and pumps
must not be installed in an enclosed space. An
enclosed space can be a cooler or small room or
closet. This may include convenience stores with
glass door self serve coolers. If you suspect CO
2
may build up in an area, venting of the BIB pumps
and/or CO
2
 monitors must be utilized.