208-230 VOLT, 60 HZ, 1 PHASE CONNECTION
All 208-230 volt models are to be permanently connected and are provided with 
four (4) field wiring leads which exit the electrical console box located in the 
machine compartment rear, next to the compressor. The cabinet circuitry is 115 
volts and the condensing unit is 208-230 volts in which the wiring includes a 
neutral and a mechanical ground. This wiring should be connected to the 
appropriate power source by a qualified electrician and must conform to all 
local electrical codes.
SPECIAL VOLTAGE CONNECTIONS
When models are ordered from the factory with special, optional voltages, 
connections should be made as required on the electrical wiring diagram 
provided on the inside compressor compartment rear next to the electrical 
console box.
START-UP CHECKLIST
After your model has been installed, leveled, cleaned, and electrically connected 
in accordance with this manual, please take the time before start-up to observe the 
following precautions to assure trouble free operation:
1. Check that all exposed refrigeration lines are free of severe dents or kinks.
2. Check the condenser fan and evaporator fans for freedom to rotate without 
any obstructions
3. Make sure that the cabinet is properly leveled (see “leveling” under 
installation and location section).
The system should run smoothly and quietly in accordance with generally accepted
commercial standards. If any unusual noises are heard, turn the unit off immediately
and check for any obstructions of the condenser or evaporator fans. Fan motors, fan
blades, or fan housings can be jarred out of position through rough handling in transit
or during installation.
Caution:
If unit is unplugged or disconnected for any reason, allow several 
minutes (5-6 minutes) before turning the unit back on to allow the system 
pressures to equalize. Disregarding this procedure could cause an overload 
and prevent the unit from operating.
REMOTE APPLICATIONS
All models are available for purchase as remote models in which case the condensing
unit is purchased separately and installed at the time of installation. All remote models
are equipped with an expansion valve located within the evaporator coil housing, and
both liquid and suction lines stubbed and extending out from the cabinet rear behind
the rear cover. Installation of the refrigeration accessories, condensing unit, and 
electrical hook-up should be performed by qualified refrigeration personnel of a 
competent refrigeration company only.