Continental Refrigerator Undercounter Refrigerator and Freezer Pizza Preparation Table ユーザーズマニュアル

ページ / 33
FIGURE 3
CASTERS MUST BE TIGHT TO CABINET BOTTOM
INSTALLING CONDENSATE EVAPORATOR
No floor drains or plumbing connections are required since all models use an 
automatic condensate water evaporating system. All models utilize a unique 
hot air condensate water evaporating system which is completely self-contained 
and no further assembly or maintenance is required. In some adverse conditions 
such as high ambient temperature, high humidity, extremely heavy usage, frequent
loading for prolonged periods of time, and heavy pan loading, an optional electric 
condensate evaporator pan may be purchased as an accessory. An electric 
condensate evaporator pan is also supplied with all remote models. To install the 
condensate pan, remove all rear cabinet cover screws and install the mounting 
bracket on the case rear next to and behind the compressor as shown in figure 4.
Slide the condensate pan onto the bracket, install the drain tube into the pan 
making sure it is not blocked or kinked, and plug the ten foot power cord into the
receptacle labeled “vaporizer” located on the compressor compartment electrical 
box. 
Important Note:
It is extremely important to be sure that the condensate pan is 
plugged into its correct receptacle labeled “vaporizer” and that the condensing 
unit is plugged into its correct receptacle labeled “condensing unit”.
9