KitchenAid SIDE BY SIDE REFRIGERATOR ユーザーズマニュアル

ページ / 56
8
3. Use a hex-head socket wrench to adjust the leveling screws. 
Turn the leveling screw to the right to raise that side of the 
refrigerator or turn the leveling screw to the left to lower that 
side. It may take several turns of the leveling screws to adjust 
the tilt of the refrigerator. See Graphic 7.
NOTE: Having someone push against the top of the 
refrigerator takes some weight off the leveling screws and 
rollers. This makes it easier to adjust the screws. 
4. Open both doors again and check to make sure that they 
close as easily as you like. If not, tilt the refrigerator slightly 
more to the rear by turning both leveling screws to the right. It 
may take several more turns, and you should turn both 
leveling screws the same amount.
5. Replace the base grille.
NOTE: Be sure to refasten the Tech Sheet behind the base grille.
Connect the Water Supply
Read all directions before you begin.
IMPORTANT: If you turn the refrigerator on before the water line 
is connected, turn the ice maker OFF.
Connect to Water Line
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long 
enough to clear line of water.
3. Locate a ½" to 1
¹⁄₄" (1.25 cm to 3.18 cm) vertical cold water 
pipe near the refrigerator.
IMPORTANT:
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the 
pipe, not the bottom. This will help keep water away from 
the drill and normal sediment from collecting in the valve.
4. Determine the length of copper tubing you need. Measure 
from the connection on the lower left rear of refrigerator to the 
water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use 
¹⁄₄" 
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure 
both ends of copper tubing are cut square. 
5. Using a grounded drill, drill a 
¹⁄₄" hole in the cold water pipe 
you have selected.
 
6. Fasten the shutoff valve to the cold water pipe with the pipe 
clamp. Be sure the outlet end is solidly in the 
¹⁄₄" (6.35 mm) 
drilled hole in the water pipe and that the washer is under the 
pipe clamp. Tighten the packing nut. Tighten the pipe clamp 
screws slowly and evenly so the washer makes a watertight 
seal. Do not overtighten or you may crush the copper tubing. 
7. Slip the compression sleeve and compression nut onto the 
copper tubing as shown. Insert the end of the tubing into the 
outlet end squarely as far as it will go. Screw compression nut 
onto outlet end with adjustable wrench. Do not overtighten. 
8. Place the free end of the tubing in a container or sink, and 
turn ON the main water supply. Flush the tubing until water is 
clear. Turn OFF the shutoff valve on the water pipe. Coil the 
copper tubing.
Connect to Refrigerator
Style 1 - Connection to Water Valve
1. Unplug refrigerator or disconnect power.
2. Attach the copper tube to the valve inlet using a compression 
nut and sleeve as shown. Tighten the compression nut. Do 
not overtighten.
3. Use the tube clamp on the back of the refrigerator to secure 
the tubing to the refrigerator as shown. This will help prevent 
damage to the tubing when the refrigerator is pushed back 
against the wall.
4. Turn shutoff valve ON. 
5. Check for leaks. Tighten any connections (including 
connections at the valve) or nuts that leak. 
6. The ice maker is equipped with a built-in water strainer. If 
your water conditions require a second water strainer, install 
it in the 
¹⁄₄" (6.35 mm) water line at either tube connection. 
Obtain a water strainer from your nearest appliance dealer.
Style 2 - Connection to Water Line
1. Unplug refrigerator or disconnect power.
2. Remove and discard the shipping tape and the black nylon 
plug from the gray, coiled water tubing on the rear of the 
refrigerator.
3. If the gray water tube supplied with the refrigerator is not long 
enough, a 
¹⁄₄" x ¹⁄₄" coupling is needed in order to connect the 
water tubing to an existing household water line. Thread the 
provided nut onto the coupling on the end of the copper 
tubing. 
NOTE: Tighten the nut by hand. Then tighten it with a wrench 
two more turns. Do not overtighten. 
4. Turn shutoff valve ON.
5. Check for leaks. Tighten any nuts or connections (including 
connections at the valve) that leak.
Style 3 - Connection to Shut-off Valve
1. Unplug refrigerator or disconnect power.
2. Remove and discard the shipping tape and the black nylon 
plug from the gray, coiled water tubing on the rear of the 
refrigerator.
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
E. Compression sleeve
F. Shutoff valve
G. Packing nut
A
B
C
D
E
F
G
A. Tube clamp
B. Copper tubing
C. Compression nut
D. Valve inlet
A. Refrigerator water tubing
B. Nut (provided)
C. Bulb
 D. Coupling (provided)
E. Ferrule (purchased)
F. Nut (purchased)
G. Household water line
A
B
C
D
A
B
C
D
E
F
G