6.3.2   Edge Pre-select (EPS) Trigger Mode 
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is 
the fixed shutter speed set by registers. The accumulation can be LVAL synchronous or LVAL 
asynchronous. The resulting video signal will start to be read out after the selected shutter 
time.  
For timing details, refer to fig. 20 through fig. 27. 
 
To use this mode:  
Set function: 
Trigger mode                    EPS 
 
Scanning 
                 Full, Partial 
 
Vertical binning                   ON / OFF (CM-141MCL only) 
 
Shutter mode                       Preset, Programmable, Fine Exposure 
 
Shutter speed                      1/60 to 1/10,000 
 
 
Programmable exposure       2 L to 1052 L   
 
Accumulation (Auto)            LVAL Sync / LVAL a-sync 
 
Other functions and settings 
Input: 
External trigger                   12-pin Hirose or Camera Link 
 
 
Important notes on using this mode
 
 
Trigger pulse >2 LVAL to <1 FVAL) 
 
The following table shows minimum trigger interval in synchronous accumulation mode 
Full scan 
1054  L 
2/3 Partial 
774 L 
1/2 Partial 
635L 
1/4 Partial 
427 L 
1/8 Partial 
323 L 
1/2 V Binning 
529 L 
           In the case of asynchronous mode, the exposure time should be added to the above 
table. 
 
LVAL sync timing 
 
    
Fig. 26   Edge Pre-select LVAL sync Timing