JAI 141PMCL-RA 사용자 설명서

다운로드
페이지 52
 
CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA
 
 
 
25
   
LVAL async timing 
 
 
 
Fig.27   Edge Pre-select LVAL a-sync Timing 
 
6.3.3   Pulse Width Control (PWC) Trigger Mode 
In this mode the accumulation time is equal to the trigger pulse width. Here it is possible to 
have a long time exposure. The maximum recommended time is <2 seconds. 
The accumulation can be LVAL synchronous or LVAL asynchronous.  
The resulting video signal will start to be read out after the trigger rising edge.  
For timing details, refer to fig. 20 through fig. 25 and fig.28 and 29. 
 
To use this mode:  
Set function:        Trigger mode  
         
PWC 
Scanning 
             
Full, Partial   
 
Vertical binning 
         
ON / OFF (CM-141MCL only) 
Accumulation (Auto)            
LVAL sync / LVAL a-sync   
Other functions and settings 
Input:                   External trigger  
 
12-pin Hirose or Camera Link 
 
  
  
Important notes on using this mode
 
 
Trigger pulse width >2LVAL to <2 seconds 
 
The following table shows minimum trigger interval in synchronous accumulation mode  
Full scan 
1054 L 
2/3 Partial 
774 L 
1/2 Partial 
635 L 
1/4 Partial 
427 L 
1/8 Partial 
323 L 
V Binning 
529 L 
 
         In the case of asynchronous mode, the exposure time should be added to the above 
table.