Typical Installation
1.  Remove  existing  wall  switch  from  junction 
box.
2.  Connect electrical leads of sensor as shown in 
Figure 3. Before installing sensor into junction 
box, make sure there is no wire exposed at 
each connection.
3.  Mount sensor into junction box using two large 
mounting screws provided.
4.  For test purposes, use a small screwdriver to 
turn the TIME control fully counterclockwise 
and the LIGHT control fully clockwise. Turn 
the power back on at the circuit breaker.
5.  Set mode selection switch to the AUTO posi-
tion. When unit stabilizes (about 1 minute), 
the sensor is ready to detect motion. If sensor 
detects  motion,  the  lights  will  turn  on. The 
lights will turn off 5 seconds after motion is 
no longer detected.
OFF
ON
AUT
O
T I M E
L I G H T
+
Test
20
15
1
5
10
Green ground wire to 
junction box screw or 
grounding wire.
Black
Black
Line 
“Hot”
Neutral 
Return
Lighting Load
 WARNING: Turn  power  off  at  the 
circuit breaker before wiring.
INSTALLING SENSOR
Removing Control Panel Cover
1.  Remove the decorative cover plate (secured 
by two small screws).
2.  Press in with screwdriver as shown in Figure 
2. Swing control panel cover out to remove.
Mode 
Selection
Switch
Control 
Panel
Control Panel 
Cover
Figure 2 - Removing Control Panel Cover
Figure 3 - Connecting Electrical Leads of Sensor
To Lighting Load