Heath Zenith 6105 사용자 설명서

다운로드
페이지 12
3
595-4881-11
USING MOTION SENSOR 
WALL SWITCh
MOdE SELECTION SWITCh
This  switch  allows  you  to  selects  one  of  three 
modes of operation: OFF, AUTO, or ON.
OFF: Lights stay off.
AUTO:  Lights  automatically  come  on  when 
motion is detected and the existing light is below 
the set level.
ON: Lights stay on continuously.
AdJUSTMENTS
Time
There are 6 preset selections for the amount of 
time the lights stay on: Test (5 seconds), 1, 5, 10, 
15, and 20 minutes. Use a small, phillips screw 
driver to adjust the TIME control (see Figure 4). 
Turn the TIME control until it “snaps” into the 
desired time position.
Light Level
You can adjust the sensor’s sensitivity to existing 
light. Use a small Phillips screw driver to adjust 
the LIGHT control (see Figure 4). By turning the 
control fully clockwise, the sensor will turn lights 
on even in full daylight. By turning the control fully 
counterclockwise, the sensor will only turn lights 
on when the existing light is very low.
Adjusting the Photocell
1.  When the existing light in the room is at the 
level you want the lights to turn on, set the mode 
selection switch to the AUTO position.
2.  Adjust the TIME control to the 5 second posi-
tion.
3.  Adjust  the  LIGHT  control  to  the  minimum 
dark position (fully counterclockwise).
4.  Wait for the lights to turn off.
5.  Slightly turn the LIGHT control clockwise. 
Wait 2 seconds, then move your hand in front 
of the sensor. If lights controlled by the sensor 
do not come on, repeat this step until they do. 
The light will now come on when the light level 
is at or below the present level and motion is 
detected.
COMPLETING INSTALLATION
1.  Replace  control  panel  cover  and  attach  the 
decorative wall plate. In installations where 
the  Heath
®
/Zenith  motion  sensor  switch  is 
combined with other switches or outlets on 
an expanded box, you will need to purchase 
a combination wall plate. Various combination 
wall plates are available at home centers and 
electrical supply stores.
2.  Slide the mode selection switch a couple times 
to make sure it moves freely.
SPECIFICATIONS
Electrical Input ................................................................................................................120V, 60 Hz.
Fluorescent Load ...................................30 Watts minimum, Up to 400 Watts Maximum Rapid Start
Motor Load ...................................................................................................Up to 1/8 HP Maximum
Incandescent ...........................................................................Up to 500 Watts Maximum at 120VAC
On-Time ..........................................................................Adjustable approximately 5 sec. to 20 min.
Photocell Sensor ........................................................................ From full daylight to less than 1 FC.
Coverage ................................ up to 15 ft. (4.6 m) at 150°, up to 30 ft. (9.1 m) in front of the sensor
T I M E
L I G H T
+
Test
20
15
1
5
10
5 Seconds
Any Light Level
20 minutes
Dark (low light level)
Figure 4 - Time and Light Adjustments
HeathCo LLC reserves the right to discontinue products and to change specifications at any time 
without incurring any obligation to incorporate new features in products previously sold.