DESCRIPTION
Air King® 12" (30,4 cm) and 16"  (40,6 cm) Wall Mounted Oscillating 
Fans offer  rotary knob/pull cord speed control, variable oscillation, 
a permanent split capacitor motor and OSHA-complying front steel 
mesh grill with a 6 ft (1,8m) 18/3 cord set.
SPECIFICATIONS
Motor  .................................120V, 60 Hz (12" 30,4 cm)
 
120V, 60 Hz (16" 40,6 cm)
Blade diameter ...................12" ( 30,4 cm) Model 4C630P/9012P 
                                            16" (40,6 cm) Model 4C631Q/9016Q
Speeds ...............................3
Control ...............................Rotary Knob/Pull Cord
Air flow distribution ...........90° 
Approvals ...........................ETL Listed. Close mesh Fan Guard 
 
meets OSHA requirements.
1
2084077
Rev. G 9/09
WALL MOUNTED  
OSCILLATING FANS
12" (30,4 cm) MODEL 4C630P/9012P 
16" (40,6 cm) MODEL 4C631Q/9016Q
8
2084077
Rev. G 9/09
MODELO 4C630P/9012P y 4C631Q/9016Q
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should 
always be followed to reduce the risk of fire, electric shock 
and injury to person, including the following:
1.  Read all instructions before using Fan.  
2.  Make certain that the power source conforms to the electrical 
requirements of the Fan.
3.  Use this Fan only as described in this manual.  Any other use 
not recommended by the manufacturer may cause fire, electrical 
shock, or injury to persons.
4.  Unplug  power  cord  before  installing,  servicing,  or  moving  the 
Fan.
WARNING:  DO  NOT  DEPEND  UPON  THE  ON-OFF  SWITCH 
AS  THE  SOLE  MEANS  OF  DISCONNECTING  POWER  WHEN 
INSTALLING OR SERVICING THE FAN.  ALWAYS UNPLUG THE 
POWER CORD.
5.  This  Fan  must  NOT  be  used  in  potentially  dangerous 
locations such as flammable, explosive, chemical-laden 
or wet atmospheres.
6.  DO NOT use Fan in or near a window.  Rain may create an 
electrical hazard.
7.  The  power  cord  is  equipped  with  a  three-prong  grounded 
plug that must be inserted into a matching receptacle.  Under 
no circumstances should the grounding prong be cut off the 
plug.  Where a two-prong wall receptacle is encountered, it 
must be replaced with a properly grounded three-prong re-
ceptacle installed in accordance with the National Electrical 
Code  (NEC)  and  all  applicable  local  codes  and  ordinances.  
This work must be done only by a qualified electrician, using 
copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER 
IS NOT RECOMMENDED.  IMPROPER CONNECTION MAY CRE-
ATE THE RISK OF ELECTRIC SHOCK.  USE OF SUCH ADAPTERS 
IS NOT PERMITTED IN CANADA.
WARNING:  THIS  PLUG  IS  A  SAFETY  FEATURE.  TO  REDUCE 
THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INjURY, 
DO  NOT  REMOVE,  REPLACE,  REPAIR  OR  TAMPER  WITH 
THE  ORIGINALLY  SUPPLIED  PLUG.  IF  THE  FAN  DOES  NOT 
FUNCTION PROPERLY, IT MAY bE DUE TO THE SAFETY DEVICE 
INCORPORATED IN THIS PLUG. 
8.  Where possible, avoid the use of extension cords.  If they must 
be used, minimize the risk of overheating by ensuring that they 
are UL listed.  Never use a single extension cord to operate more 
than one Fan.
9.  NEVER operate any Fan with a damaged cord or plug or after 
the Fan malfunctions, has been dropped or damaged in any 
manner.  
10.Do not insert or allow fingers or foreign objects to enter any 
ventilation or exhaust opening as it may cause an electric shock 
or fire, or damage the Fan.  Do not block or tamper with the Fan 
in any manner while it is in operation. 
11.Always  place  the  Fan  on  a  stable,  flat,  level  surface  when 
operating, to avoid the chance of the Fan overturning.  Locate 
the Power Cord so the Fan or other objects are not resting on it.  
Do not run Power Cord under carpeting.  Do not cover Power 
Cord with throw rugs, runners, or the like.  Arrange Power Cord 
away from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations.  Never 
locate  a  Fan  where  it  may  fall  into  a  bathtub  or  other  water 
container.
13.Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including 
areas where livestock, poultry or other animals are confined. 
Please  refer  to  National  Electric  Code  (NEC)  Article  547-7 
(2008), or applicable state or local codes or standards relating 
to electrical requirements for Agricultural Buildings. THIS FAN 
DOES  NOT  MEET  THE  REQUIREMENTS  OF  NEC  ARTICLE 
547-7 (2008).
15.This Fan is not suitable for use in hazardous locations. Please 
refer to National Electric Code (NEC) Article 500 or applicable 
state  or  local  codes  or  standards  relating  to  electrical 
requirements for Hazardous locations. THIS FAN DOES NOT 
MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).
 
 
WARNING:
 
REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK  –  DO  NOT  USE  THIS  FAN  WITH  ANY  SOLID 
STATE SPEED CONTROL DEVICES.
SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-
SCRIBED.  PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY 
WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
 RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  
OPERATING INSTRUCTIONS & PARTS MANUAL
LISTA DE REPUESTOS
2060316 
2060316 
Placa de Montaje 
1
2090003 
2090003 
Tornillo Phillips #8 x 1-1/4" 
2
02090045A 
02090045A 
Tornillo Phillips Tipo 25 #8 x 3/4" 6
02090272 
02090272 
Pata de Caucho 
2
2060202 
2060202 
Placa Tracera para Colgar 
1
2010554 
2010554 
Tapa del Interruptor 
1
2090008 
2090008 
Tornillo Phillips #8 x 1/2" 
2
02055047 
02055047 
Interruptor con Cordón 
 
 
 
Accionador 
1
7091854 
7091854 
Plastico Protector 
2
10  2010512P 
2010512P 
Cuerpo 
1
11  2090539 
2090539 
Casquillo del Cordón Accionador 1
12  02090744 
02090744 
Tire Cuerda 
1
13  02035035 
02035036 
Conjunto de Motor 
1
14  02010162B 
02010162B 
Placa de Trinquete 
1
15  02090518 
02090518 
Resorte de Elevación 
1
16  02090521A 
02090521A 
Eje de Elevación 
1
17  02090033 
02090033 
Tuerca Hexagonal 
1
18  02010548A 
02010548A 
Boton Tipo H.C. 
2
19  2010131 
2010131 
Botón del Interruptor (Rotatorio) 1
20  02050009FPB 
02050009FPB 
Cordón Eléctrico 
1
21  2011212 
2011200M 
Rejilla Plástica Trasera 
1
22  2010359 
2010359 
Tuerca de Seguridad 
1
23  2010008 
2011013 
Aspa 
1
24  2010058 
2010090 
Tapa 
1
25   02096217 
02096214
I
 
Rejilla Frontal 
1
26  02010381A 
02010381A 
Ornamento  
1
Ref.           
Parte No. for Modelo
No.  4C630P/9012P 
4C631Q/9016Q 
Descripción 
Cant.
24
2
7
 
MODEL  
 
4C630P/9012P 
                   4C631Q/9016Q
 
SPEED 
HIGH 
MED 
LOW 
HIGH 
MED 
LOW
 
CFM  
940 
800 
700 
1510 
1380 
1190
 
M
3
/s  
0.44 
0.38 
0.33 
0.71 
0.65 
0.56
 
RPM  
1470 
1320 
1100 
1411 
1280 
1110
 
Amps  
0.46 
0.37 
0.32 
0.80 
0.57 
0.47
 
Watts 
51 
44 
39 
87 
70 
57
 
dBA 
45 
41 
36 
51 
47 
42