and the number “1” should remain in the lower right hand corner of 
the display. The “1” and “OFF” signify the turn off time for the first 
program. Set the turn off time using the 1…7, h, and m buttons in 
the same way as described above and continue on to the second 
through sixth programs. When setting the ventilation programs, 
you can return to the current time display by sliding the switch in 
the upper right corner of the timer to RUN. The slide switch in the 
upper right must be set to RUN for the timer to operate with the 
scheduled programs.
The slide switch in the upper left of the timer is used to choose 
between automatic and manual operation of the timer relay. When 
the slide switch in the upper left of the timer is set to AUTO mode, 
the central conditioning unit will ventilate when the scheduled 
programs call for ventilation. When the slide switch in the upper 
left of the timer is set to manual (set to hand symbol on the the 
right), the operation of the timer is controlled by the I/O button only. 
Pressing the I/O button will switch the ventilation timer between 
ON (detent) and OFF (detent). As you press the I/O button, “ON” or 
“OFF” will be displayed to the right of the time. The “ON” or “OFF” 
to the right of the time will indicate if the ventilation timer is on or 
off. The I/O button will manually override scheduled programs if the 
timer is in AUTO mode.
4.6 High Efficiency Air filter
A high efficiency air filter is available for the Ultra-Aire . This filter is 
rated 90%-95% efficient by ASHRAE Dust Spot Test Method 52-76. 
This filter is much more efficient than the standard air filter and is 
able to catch much smaller particles that can aggravate allergies.
The high efficiency air filter is 4 inches thick and should be 
installed in the filter enclosure directly below the standard air filter. 
The standard air filter will act as a pre-filter for the high efficiency 
air filter and will prolong the life of the high efficiency air filter. 