STUDER INNOTEC 
XP-COMPACT 
 XP-COMPACT 
V5.4 
20/77 
4.9  The Solar charge controller (option) 
The XP-COMPACT also has a Solar Charge Controller built in. For charging the 
batteries, Solar modules can be connected to the screw terminal SOLAR +/-. The in-
built controller is a „Shunt controller“ for the maximum input current of 30A for XPC 
1400-12 and XPC 2200-24 and 20A for XPC 2200-48. The operating voltage of solar 
panels to be connected must match the actual operating voltage of the XP-
COMPACT and never exceeds the max. rated value. 
Under no circumstances should any other systems such as wind-generator be 
connected at the input of the Solar Charge Controller. 
The Solar Charge Controller works automatically and is always in operation. As soon 
as the energy is delivered from the Solar Charge Controller, LED 3 “SOLAR 
CHARGE” is lit and the batteries are being charged. The Solar Charge Controller 
works even when the Battery Charger is functioning. The way of working is the 
principally the same as that of the Battery Charger. The function is described in the 
section on Battery Charger. The programming and the adjustments are carried out in 
accordance with the same conditions. Check with your battery supplier which 
adjustments must be carried out for your battery. 
4.10  The Multifunctional Contact 
In the XP-COMPACT there is a built-in programmable power relay. The potential-free 
change-over contact (NO – NC) of this power relay is connected to the screw 
terminal AUX CONTACT. 
Maximum Contact load:  230Vac / 12Vdc / 24Vdc / 16A ! 
 
> 36Vdc / 3A ! 
With the Push Button 21 „AUXILIARY CONTACT“ the contact can be manually 
switched on or off independently from programming and from the operating situation. 
The LED 5 “Contact active” shows the status of the contact. The drawing up the 
screw terminal “AUX CONTACT” is the inactive position mode, LED 5 “Contact 
active” off. 
The switching on and off of this contact can be freely programmed for every 
operating situation of the XP-COMPACT witch situation is indicated with a LED. 
There is no limitation to its application and it is left to your wishes as to where and 
how you would like to use it. The example and the setting of this contact are 
explained in chapter 5.4. 
In factory we program this for a dysfunction alarm. The contact is active when one of 
these situations is detected: 
−  Over temperature (LED 10 lit) 
−  Overload (LED 11 lit) 
−  Over or less voltage of batteries (LED 12 lit or blinking)  
−  XP-COMPACT is turned off manually or with a fault (LED 13 lit) 
In case this function is not wished, it must be modified by programming according to 
procedure in chap. 5.4.