5
www.chpower.com
Operating Instructions and Parts List
Maintenance
 
 
Disconnect, tag and lock out 
power source, then release 
all pressure from the system 
before attempting to install, service, 
relocate or perform any maintenance.
Check compressor often for any visible 
problems and follow maintenance 
procedures each time compressor is 
used.
 
Safety valve must  
 be replaced if it 
cannot be actuated or it leaks air after 
ring is released.
1.  Turn compressor off and release 
pressure from system. (To release 
pressure from system, pull ring 
on ASME safety valve. Deflect 
escaping air by shielding valve with 
one hand as you pull ring with 
other hand.) Pull ring until tank is 
empty.
 
A large amount of  
 fast moving air 
will be released when the safety valve 
is opened with pressure in the tank. 
Wear ANSI approved Z87.1 safety 
glasses.
2.  Drain moisture from tank by 
opening drain valve underneath 
tank. Tilt tank to remove all 
moisture.
3.  Clean dust and dirt from tank, 
air lines and pump cover while 
compressor is still OFF.
aSMe SaFety vaLve
 
Do not remove or   
 attempt to adjust 
the safety valve!
Check the safety valve by performing 
the following steps: 
1.  Plug the compressor in and run 
until shut off pressure is reached. 
2.  Wearing safety glasses, pull the 
ring on the safety valve to release 
pressure from compressor tank. 
Use your other hand to deflect 
fast-moving air from being 
directed toward your face. 
3.  The safety valve should 
automatically close at 
approximately 40 psi - 50 psi. If 
the safety valve does not allow 
air to be released when you pull 
on the ring, or if it does not close 
automatically, it MUST be replaced.
Figure 4
DraIn tank
With compressor shut off and pressure 
released, drain moisture from tank by 
opening drain valve underneath tank. 
Tilt tank to completely drain moisture.
cLeanInG
Turn power OFF and clean dust and 
dirt from pump cover, tank, and air 
lines.
IMPOrtant: Unit should be located 
as far from spraying area as hose will 
allow to prevent over-spray from 
clogging air filter.
LUbrIcatIOn.
This is an oilless type compressor 
requiring no lubrication.
enD OF OPeratIOn/StOraGe
1.  Turn ON / OFF switch to the OFF 
position.
2.  Unplug power cord from wall 
outlet and wrap around handle 
area to prevent damage when not 
in use.
3.  Wearing safety glasses drain tank 
of air by pulling the ring on the 
safety valve. Use other hand to 
deflect fast moving air from being 
directed toward your face.
4.  Drain tank of condensation by 
opening drain valve on bottom 
of tank. Tank pressure should be 
below 10 psi when draining tank.  
5.  Air hose should be disconnected 
from compressor and hung open 
ends down to allow any moisture 
to drain.
6.  Compressor and hose should be 
stored in a cool, dry place.
technIcaL ServIce
For information regarding the 
operation or repair of this product, 
please call 1-800-543-6400.
MaIntenance ScheDULe
OPeratIOn
DaILy
WeekLy
MOnthLy
DRAIN TANK
l
CHECK SAFETY VALVE
l
CLEAN UNIT
l