Datalogic Scanning 1000 사용자 설명서
INSTALLATION
21
2
An anti-disturbance filter (debouncing) is implemented on the input, and is software
programmable. The
programmable. The
input active state can be defined by the user as well. Refer to the
digital I/O folder in the VisiSet™ Help On Line for further details.
2.3.5 Outputs
One optocoupled general purpose output is available on the 25-pin connector. The
pinout is the following:
Pin Name
Function
16
OUT3+
Configurable digital output 3 - positive pin
17
OUT3-
Configurable digital output 3 - negative pin
It is typically used to signal the data collection result. It can also be used to control an
external lighting system
external lighting system
The idle state, the activation/deactivation events and the other configuration
parameters can be defined by the user. Refer to the Digital I/O folder in the VisiSet™
Help On Line for further details.
parameters can be defined by the user. Refer to the Digital I/O folder in the VisiSet™
Help On Line for further details.
MATRIX
USER INTERFACE
Vext 30 Vdc max
+
-
I
Load
V
Out
Figure 21 - Open Collector Output Connection
The electrical features of the output are the following:
OUTPUT I
Load
V
Out
Open
0 mA
30 Vdc Max
Closed
10 mA
1.8 Vdc Max
P
D
= V
Out
×
I
oLoad