Datalogic 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for 
Datalogic 2 of 5 Length Control
.
Length 1 is the minimum label length if in 
Variable Length
 Mode, or the first fixed 
length if in 
Fixed Length
 Mode. The length includes the barcode’s check and data char-
acters.
The length can be set from 2 to 50 characters in increments of two.
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50). The length must be an 
even number.
2. Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT I 2 of 5 LENGTH 1 SETTING.
5. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a 
two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See 
Table 27
 for some examples of how to set this feature.
Table 27. Datalogic 2 of 5 Length 1 Setting Examples
NOTE
If you make a mistake before the last character scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to yield 
two digits
02
06
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT Datalogic 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘2’
 ‘0’ and ‘6’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE