Datalogic Scanning PD7100 사용자 설명서

다운로드
페이지 324
Datalogic 2 of 5
Product Reference Guide
        
         211
Datalogic 2 of 5 — cont.
Datalogic 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for 
Datalogic 2 of 5 Length Control
.
Length 2 is the maximum label length if in 
Variable Length
 Mode, or the second fixed 
length if in 
Fixed Length
 Mode. The length includes the barcode’s check and data char-
acters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length 
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50, or 0 to ignore this length). 
The length must be an even number.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 
05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT Datalogic 2 of 5 LENGTH 2 SETTING.
5. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a 
two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See 
Table 28
 for some examples of how to set this feature.
Table 28. Datalogic 2 of 5 Length 2 Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to yield 
two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From 
Appendix E, Keypad
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6