DFE-Gold Module Shutdown Procedure
4-6 Troubleshooting
DFE-Gold Module Shutdown Procedure
The DFE‐Gold modules installed in a Matrix E7, Matrix N3, Matrix N5, or Matrix N7 
chassis are interdependent and operate under a single IP address as a single, distributed 
switch system (hardware, databases, and persistent storage). In this operating 
environment, the DFE‐Gold module must shut down in an orderly fashion to ensure that 
the other modules in the system and other devices on the network are notified of the 
impending change. The device(s) can then make intelligent decisions that ensure the 
stability of the network before the change is made, thereby increasing network 
availability.
Port(s) goes into 
standby for no 
apparent reason.
Loop condition 
detected.
Verify that Spanning Tree is enabled. Refer to the 
Matrix DFE-Gold Series Configuration Guide for 
the instructions to set the type of STA.
Review the network design resolve loops. 
If the problem continues, contact 
Enterasys Networks for technical support.
User parameters 
(IP address, device 
and module name, 
etc.) were lost 
when the module 
power was cycled, 
the front panel 
OFFLINE/RESET 
switch was 
pressed.
Position of Mode switch 
(7), Persistent Data 
Reset, was changed 
sometime before either 
cycling power or 
pressing the OFFLINE/
RESET switch, causing 
the user-entered 
parameters to reset to 
factory default settings.
Clear Persistent Data 
that was set through 
Local Management.
The module was moved 
either from slot-to-slot 
or from chassis-to-
chassis.
Reenter the lost parameters as necessary. Refer 
to the Matrix DFE-Gold Series Configuration 
Guide
 for the instructions to configure the device.
If the problem continues, contact 
Enterasys Networks for technical support.
Table 4-2 Troubleshooting Checklist  (continued)
Problem
Possible Cause
Recommended Action
Caution: Do not remove a DFE module from an operating chassis system before reading 
the following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las 
siguientes instrucciones y la información suministrada.