Enterasys Networks 4G4282-49 사용자 설명서

다운로드
페이지 90
DFE-Gold Module Shutdown Procedure
4-8 Troubleshooting
When a controlled shutdown is initiated from the OFFLINE/RESET
 switch
, you have 60 
seconds from the time the CPU starts alternately flashing amber/off until the device 
automatically restarts.
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
To reset a DFE‐Gold module without it performing an orderly shutdown routine, 
press and hold the OFFLINE/RESET switch for approximately 6 seconds. 
Removing any DFE‐Gold module from the chassis before it has been shut down is not 
recommended. The only safe time to remove a module from the chassis is after the 
completion of a shutdown and the management LED is alternately flashing amber/off.
Note:  The only safe time to remove a DFE-Gold module from the chassis is when the 
CPU LED is alternately flashing amber/off. Otherwise, system operation will be 
interrupted.
Caution: This method of shutting down a DFE module is not recommended except as a 
last resort, because all processes currently running on the module will be interrupted, 
resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE. 
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del 
módulo en funcionamiento, lo que podría resultar pérdidas de frames.