Fujitsu N800 사용자 설명서

다운로드
페이지 142
U41243-J-Z156-1-76
 39
Preparation for use and operation Configuring the server and components
4.4.1
Changing the switch settings
V
CAUTION!
Observe the safety information and the information on handling electro-
static-sensitive components in the chapter “Important notes” on 
page 11).
Ê
Shut down the server and switch it off.
Ê
Switch off all connected peripheral devices.
Ê
Disconnect the server from the line voltage by removing the power cable 
from the power outlet.
Ê
Ê
Set the switches to the desired settings (see figure 14 on page 40).
Ê
Ê
Reconnect the server to the line voltage and switch the system on for the 
change to take effect.
3
OFF No 
Password 
Clear
Retains the password.
ON
Password 
Clear
Clears the current system password.
4
OFF NOP
Reserve
ON
NOP
Reserve
5
OFF PHP
Switch
Hot-plug PCI slots, mechanical switches activated
ON
PHP
Switch
Hot-plug PCI slots, mechanical switches deacti-
vated.
Switch
Function
Description
No. Pos.
Table 2:  DIP switches settings