Cornelius 3 사용자 설명서

다운로드
페이지 74
Viper Service Manual                                 
Publication Number: 621360041TBSER
- 54 -
© 2010, IMI Cornelius Inc.
W
ATER
 P
UMP
 R
EPLACEMENT
The water pump is located just behind the water filter in the center of the unit. It 
is mounted on a bracket facing the rear of the unit. To replace the pump, perform 
the procedure in Table 47.
Figure 45. Rear View of Water Pump
2
Remove the rear cover.
3
Disconnect the spade clips from the defective capacitor.
4
Remove the mounting screw from the base of the capacitor.
5
Replace the capacitor.
6
Reverse the procedure to install the new capacitor.
7
Reconnect power to the unit.
8
9
When barrel fill is complete, perform a motor calibration. See “Calibrating a 
Table 46
Step
Action
Table 47
Step
Action
1
Disconnect power from the unit.
2
Remove the rear cover and the side panels.
3
Disconnect the CO
2
 supply from the unit.
4
Remove and drain the water supply from the unit.
5
Disconnect the quick disconnect input and output water lines from the bottom 
of the pump.
6
Disconnect quick disconnect CO
2
 input from the bottom of the pump.
7
Remove the four (4) screws and locknuts holding the pump to the mounting 
bracket.
8
Replace the pump.
9
Reverse the procedure to install the new pump.
Water Pump