The water pump is located just behind the water filter in the center of the unit. It
is mounted on a bracket facing the rear of the unit. To replace the pump, perform
the procedure in Table 47.
is mounted on a bracket facing the rear of the unit. To replace the pump, perform
the procedure in Table 47.
Figure 45. Rear View of Water Pump
2
Remove the rear cover.
3
Disconnect the spade clips from the defective capacitor.
4
Remove the mounting screw from the base of the capacitor.
5
Replace the capacitor.
6
Reverse the procedure to install the new capacitor.
7
Reconnect power to the unit.
8
Refill the barrel with product. See “Filling a Barrel” on page 29.
9
When barrel fill is complete, perform a motor calibration. See “Calibrating a
Table 46
Step
Action
Table 47
Step
Action
1
Disconnect power from the unit.
2
Remove the rear cover and the side panels.
3
Disconnect the CO
2
supply from the unit.
4
Remove and drain the water supply from the unit.
5
Disconnect the quick disconnect input and output water lines from the bottom
of the pump.
6
Disconnect quick disconnect CO
2
input from the bottom of the pump.
7
Remove the four (4) screws and locknuts holding the pump to the mounting
bracket.
8
Replace the pump.
9
Reverse the procedure to install the new pump.