Isle Royale Wood Stove
250-5763C
LISTINGS and SAFETY NOTICES
WARNING !  DO NOT ATTEMPT TO OPERATE THIS WOODSTOVE 
WITHOUT  READING AND  UNDERSTANDING  THESE  OPERATING 
INSTRUCTIONS  THOROUGHLY.    FAILURE  TO  OPERATE  THIS 
APPLIANCE PROPERLY MAY CAUSE A HOUSE FIRE.
WARNING !  THE OUTSIDE SURFACES OF THIS UNIT WILL BECOME 
ExTREMELY HOT DURING USE.  ALWAYS KEEP CHILDREN AWAY 
WHILE IT IS OPERATING AND DO NOT LET ANYONE OPERATE 
THIS APPLIANCE  UNLESS  THEY ARE  FAMILIAR  WITH  THESE 
OPERATION INSTRUCTIONS.
WARNING!  NEVER DRAW OUTSIDE COMBUSTION AIR FROM A 
WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED 
SPACE SUCH AS AN ATTIC OR GARAGE.
These installation instructions describe the installation and opera-
tion of the 
QUADRA-FIRE ISLE ROYALE woodstove.  This stove 
meets the U.S. Environmental Protection Agency’s 1990 particulate 
emission standards.  The stove is listed by OMNI-Test Laborato-
ries, Inc. to UL Safety Standard 1482, and ULC S627, and (UM) 
84-HUD., Report number 061-S-18-2.   This stove is approved for 
mobile home installations when not installed in a sleeping room and 
when an outside combustion air inlet is provided.  The structural 
integrity of the mobile home floor, ceiling, and walls must be main-
tained.  The stove must be properly grounded to the frame of the 
mobile home and only use listed double-wall pipe.  Outside Air Kit, 
Part 831-1780 must be installed in a mobile home installation. 
Check with your local building code agency before you begin your 
installation to ensure compliance with local codes, including the 
need for permits and follow-up inspections.  Be sure local build-
ing codes do not supersede UL specifications and always obtain 
a building permit so that insurance protection benefits cannot be 
unexpectedly cancelled.  If any assistance is required during instal-
lation, please contact your local dealer.
Inspect and clean vent system frequently in accordance with the 
instructions contained in this manual.  Do not connect this unit to 
a chimney serving another appliance.
When using optional Blower, Part 831-1701, route power cord away 
from unit. Do not route cord under or in front of appliance.  
Do not elevate fire. Build wood fire directly on firebrick.  
Do not overfire - if heater or chimney connector glows, you are 
overfiring.  Stove thermometer recommended.
Operate only with the door closed unless using a firescreen.  Open 
only to add fuel to the fire.  Operating with the door open can cause 
hot embers or sparks to fall out and a fire may result.
INSTALLATION MATERIALS NEEDED FOR YOUR SAFETY
CHIMNEY CONNECTOR (also known as flue pipe or stove pipe):  
The chimney connector joins the stove to the chimney (
see page 
11).  It must be 6 inch (152mm) minimum diameter 24 MSG black 
or blued steel, or an approved air-insulated double wall venting 
pipe.
THIMBLE:  A manufactured or site-constructed device installed in 
combustible walls through which the chimney connector passes 
to  the  chimney 
(see  page  11-12).    It  is  intended  to  keep  the 
walls from igniting.
CHIMNEY SYSTEMS:
1.  APPROVED MASONRY 
(see specifications on page 14) with 
at least 5/8 inch (16mm) fire clay lining joined with refractory 
cement  or  other  listed  system  suitable  for  use  with  wood 
stoves.
2.  PREFABRICATED  6  inch  (152mm)  listed  high  temperature 
(UL 103 HT or ULC S629) chimney.  Components required 
by manufacturers for installation such as the chimney support 
base, firestop (as appropriate), attic insulation shield, insulated 
tee, etc., are necessary to assure a safe chimney installation.  
Use only components manufactured for the chimney.  Chimney 
installation should meet NFPA 211 standards.
FIRE SAFETY:  To provide reasonable fire safety, the following 
should be given serious consideration:
1.  Install at least one smoke detector on each floor of your 
home to ensure your safety.  They should be located away 
from the heating appliance and close to the sleeping areas.  
Follow the smoke detector manufacturer’s placement and 
installation instructions, and be sure to maintain regularly.  
2.  A conveniently located Class A fire extinguisher to contend 
with small fires resulting from burning embers.
3.  A  practiced  evacuation  plan,  consisting  of  at  least  two 
escape routes.
4.  A plan to deal with a chimney fire as follows:
 
In the event of a chimney fire:
A.  Notify fire department.
B.  Prepare occupants for immediate evacuation.
C.  Close all openings into the stove.
D.  While awaiting fire department, watch for ignition of 
adjacent combustibles from overheated stove pipe, 
hot embers or sparks from the chimney.
VENTING SYSTEM
The  venting  system  consists  of  a  chimney  connector  and  a 
chimney.  These get extremely hot during use.  Temperatures 
inside the chimney may exceed 2000°F (1100°C) in the event of 
a creosote fire.  To protect against the possibility of a house fire, 
the chimney connector and chimney must be properly installed 
and maintained.  An approved thimble must be used when a 
connection is made through a combustible wall to a chimney.  
A chimney support package must be used when a connection 
is made through the ceiling to a prefabricated chimney.  These 
accessories are absolutely necessary to provide safe clearances 
to  combustible  wall  and  ceiling  material.    Follow  venting 
manufacturer’s clearances when installing venting system.
This stove may be connected to a lined masonry chimney or a 
listed high temperature prefabricated approved metal chimney.  
Do not connect it to a chimney serving another appliance.  To do 
so will affect the safe operation of both appliances.