Hearth & Home Technologies 823-0290 사용자 설명서

다운로드
페이지 32
R
Page 6
  September 1, 2008
Isle Royale Wood Stove
250-5763C
B
A
C
D
CLEARANCES TO COMBUSTIBLES (UL and ULC)
G
H
Ceiling
E
E
F
F
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE:  "A" ,"C" and "F" Dimensions are to the inside diameter of the flue collar.
FOR TOP VENT INSTALLATIONS:
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: ALCOVE  Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL 103 HT listed 
factory-built Class "A" chimney, or a masonry chimney.  (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove 
shall be no more than 48 inch(1220mm).  Please refer to the clearances below for minimum Alcove height requirements to top of unit.
DOUBLE WALL PIPE
IN A MASONRY FIREPLACE OR THROUGH THE WALL
 Six inch (6") (152mm) diameter listed double wall air insulated 
connector pipe with UL 103HT listed factory-built Class "A" chimney, or a masonry chimney.  (Mobile Home must be 
equipped with a spark arrestor).  Additonal specifications include a maximum 8 inch (203mm) deep mantel without 
heat shield and the following clearances. 
FOR REAR VENT INSTALLATIONS:
A
B
C
D
E
F
G
H
I
15 (381)
16 (406)
33 (838)
22 (558)
22 (558)
28 (711)
53 (1346)
18 (457)
16 (406)
13 (333)
14 (356)
29 (737)
18 (457)
6 (153)
12 (305)
53 (1346)
18 (457)
14 (356)
13 (333)
14 (356)
29 (737)
18 (457)
N/A
N/A
53 (1346)
18 (457)
14 (356)
*
 (G mantel) with shield spaced 1 inch (25mm) away from bottom mantel surface.
N/A
N/A)
33 (838)
22 (558)
N/A
N/A
36 (914)
14 (356)*
N/A
14 (356) 9 (229)
0 (00) In Masonry Wall
A
B
C
D
E
F
G
H
I
mantel
ceiling
G
I
CL
G
8" max
ceiling
mantel
26-7/16" 
(672mm)
OMNI Test Laboratories, Inc Report Ntumber 061-S-18-2