TANDBERG media2 blade mse 8510 사용자 설명서

다운로드
페이지 18
6
Initial configuration
Step one: Configure Ethernet Port A settings
The default setting for the Media2 blade Ethernet ports is auto-sensing mode. If the 
switch ports to which you connect the Media2 blade are not also set to auto-sensing 
mode, then you need to configure the Media2 blade Ethernet ports to use the same 
speed and duplex mode.
To configure Ethernet Port A, log in to the Supervisor’s web interface and go to 
Hardware > Blades
. For more information about configuring the port, refer to the 
online help accessible from the Supervisor’s web interface.
Step two: Assign an IP address to the Media2 blade
You can use the Supervisor’s web interface to configure the IP addresses of all blades 
installed in the MSE 8000. Note that all blades are supplied with DHCP enabled and 
therefore the Media blade will attempt to find an IP address. The LCD panel will 
show the IP address allocated. You can either keep this setting or assign static IP 
addresses to a blade from the Supervisor’s web interface. To view or configure the IP 
address of the Media2 blade, log in to the Supervisor and go to 
Hardware > Blades
To access the web interface of the Media2 blade, go to 
Hardware > Blades
 and click 
the IP address of that blade.
Both ends of the Ethernet connection must be configured in the same 
way. For example, either configure both ends of the link to be auto-
sensing or configure both ends to operate at the same speed and duplex.
To establish a 1000Mbps connection, both ends of the link must be 
configured as auto-sensing.
i