Operating Instructions
www.chpower.com
Assembly
 (Continued)
BReATheR InSTAllATIOn
Remove cap from oil fill opening . Install 
breather (found in parts bag with this 
manual) . See Figure 4 .
lUBRICATIOn
 
CHECK OIL LEVEL.  
  SOME UNITS 
INCLUDE OIL. Follow lubrication 
instructions before operating 
compressor.
Ensure oil drain extension and cap has 
been installed (if included) then remove 
the breather (See Figure 5) and fill 
pump oil according to the chart .
See specification label on air tank for 
pump model number and refer to the 
chart for the proper oil capacity .
OIl DRAIn exTenSIOn
Some models include an oil drain 
extension and cap (found with the 
owner’s manual) . Install the oil drain 
extension and cap before adding oil to 
the pump . To avoid oil leaks, it is highly 
recommended to apply thread seal 
tape or plumber’s putty to the threads 
on each end of the oil drain extension . 
Screw the cap onto one end of the 
extension . Remove the oil drain plug 
from the base of the pump and install 
the oil drain extension (See Figure 5) .
OIl
Use SAE 30 industrial grade air 
compressor oil or full synthetic motor 
oil like Mobil 1 10W30 . Do not use 
regular automotive oil such as 10W-30 . 
Additives in motor oil can cause valve 
deposits and reduce pump life . For 
maximum pump life, drain and replace 
oil after the first hour of run time . 
Proper oil fill level is illustrated in  
Figure 5 .
For pumps with an oil sight glass, oil 
level can be monitored and maintained 
as shown in Figure 5 .
eleCTRICAl DATA
  
 
Overheating, short-circuiting 
and fire damage will result 
from inadequate wiring.
The 120 volt, 15 amp units can be 
operated on a 120 volt 15 amp circuit 
under the following conditions:
1 .  No other electrical appliances or 
lights are connected to the same 
branch circuit .
2 .  Voltage is 120 Volts .
3 .  Circuit is equipped with a 15 amp 
circuit breaker or a 15 amp slow 
blow fuse type T (For Canada use 
Type D) .
4 .  The length of copper wire between 
the outlet and circuit breaker is not 
longer than 40 feet of 14 AWG or 70 
feet of 12 AWG .
If the above conditions cannot be met 
or if nuisance tripping of the current 
protection device occurs, it may be 
possible to operate the compressor from 
a 120 volt 20 amp circuit . See Figure 6 .
Check motor data plate for 240 volt 
compatability . A 240 volt unit must be 
operated on a 240 volt circuit . The cord 
must only plug into a 240 volt grounded 
outlet and may require a new cord and 
plug . See Figure 7 .
GROUnDInG InSTRUCTIOnS
This product must be grounded . In 
the event of an electric short circuit, 
grounding reduces the risk of electrical 
shock by providing an escape wire for 
the electric current . Unit is equipped 
with a cord that has a grounding prong .
 
Improper  
  use of 
grounding plug can result in  
a risk of electrical shock.
nOTe: Do not use grounding 
adapter .
 
When converting   
  to an alternate 
voltage, be sure the green ground wire 
of the cord connects to the ground pin 
of the plug and to the metal body of the 
pressure switch.
Pump
Approx. Oil Capacity
VS260000KB
6 .0 oz
VT470000KB
8 .5 oz
VT480000KB
8 .5 oz
Figure 4
Remove 
Cap
Install 
Breather
Figure 6
Grounded Outlet
Ground Pin
Figure 7
Grounded Outlet
Ground Pin
Dipstick
Breather
Add Oil
Oil Drain Extension*
Cap*
Full
Add
Low
Max
Dipstick Oil Read
Full
Add
Sight Glass
* Not included with all models.
Oil Fill Cap
(Dispose of
properly)
Breather
OR
Figure 5