Campbell Hausfeld VT6361 사용자 설명서

다운로드
페이지 24
5
VT6315, VT6358, VT6361
www.chpower.com
Operating Instructions
Operation
START-UP
 
This compressor  
  pump must be filled 
with oil before startup. See lubrication 
section.
 
Do not attach air  
  tools to open end of 
the hose until start-up is completed and 
the unit checks OK.
 
Never disconnect   
  threaded joints with 
pressure in tank!
1 .  Check for proper oil level . See 
Lubrication Section .
2 .  Open tank drain valve .
3 .  Turn pressure switch lever or knob 
to OFF position and plug in power 
cord .
4 .  Turn pressure switch lever or knob to 
AUTO position and run unit for 30 
minutes to break in the pump parts 
(See Figure 8) .
5 .  Turn regulator knob fully 
counterclockwise . Compressor will 
build to maximum preset pressure 
and shut off .
6 .  Turn regulator knob clockwise to 
cause air to bleed off . Compressor 
will restart at preset pressure .
7 .  Turn pressure switch lever or knob to 
OFF position and unplug powercord . 
Slowly turn regulator knob clockwise 
to allow all air pressure to be 
released . Do not proceed to the next 
step until the tank pressure reaches 
zero (0) .
Maintenance
 
 
Disconnect, tag and lock out 
power source, then release 
all pressure from the system 
before attempting to install, service, 
relocate or perform any maintenance.
All repairs should be performed by an 
authorized service representative .
FOR eFFICIenT OPeRATIOn:
Perform the following test to verify free 
operation of the safety valve weekly 
and follow maintenance schedule . 
1 .  Pull ring on safety valve and allow 
the ring to snap back to normal 
position (see Figure 9) . This valve 
automatically releases air if the 
tank pressure exceeds the preset 
maximum .
 
Do not attempt to  
  tamper with this 
valve. This valve should be checked 
occasionally. If air leaks after the ring 
has been released, or the valve is stuck 
and cannot be actuated by the ring, the 
safety valve must be replaced.
 
A large amount of  
  fast moving air will 
be released if this valve is actuated with 
pressure in the tank.
2 .  With motor OFF and unplugged, 
clean debris from motor, flywheel, 
tank, air lines and pump cooling fins .
TeChnICAl SeRVICe
For information regarding the operation 
or repair of this product, please call  
1-800-543-6400 .
8 .  Attach hose, then add chuck or 
other tool to open end of hose . Plug 
in powercord . Turn pressure switch 
lever to AUTO position . When full 
pressure is reached turn regulator 
knob clockwise until desired outlet 
pressure is achieved .
9 .  After use, turn pressure switch lever 
or knob to the OFF position .
10 . If compressor is not used for a long 
time period, bleed air from line 
and use drain valve to drain water 
from the tank . Then, follow the 
maintenance schedule .
nOTe: Electric models are equipped 
with a pressure switch that 
automatically turns the motor OFF 
when the tank pressure reaches a preset 
level . After air is used from the tank and 
drops to a preset low level, the pressure 
switch automatically turns the motor 
back on .
AU
TO / OFF 
Figure 8
Knob 
Auto/Off
Lever - Off
Lever - Auto
MOISTURe In COMPReSSeD AIR
Moisture in compressed air will form 
into droplets as it comes from an air 
compressor pump . When humidity 
is high or when a compressor is in 
continuous use for an extended 
period of time, this moisture will 
collect in the tank . When using a 
paint spray or sandblast gun, this 
water will be carried from the tank 
through the hose, and out of the 
gun as droplets mixed with the spray 
material .
IMPORTAnT: This condensation will 
cause water spots in a paint job, 
especially when spraying other than 
water based paints . If sandblasting, it 
will cause the sand to cake and clog 
the gun, rendering it ineffective .
A filter in the air line, located as 
near to the gun as possible, will help 
eliminate this moisture .
Figure 9