efd 741md-ss 사용자 가이드

다운로드
페이지 4
 
O-ring #7806
Retaining 
washer
#7807
Packing spring
#7808
Needle packing assembly 
#7810
 
O-ring #4049
Inlet fitting
#79005
(2) Body mounting 
screws HW6-32X1
Fluid body 
#7430-SS (stainless steel)
Nye gel lubricant, 1 gram
foil packet (not shown)
#H-147-P
Retaining nut only
#7405-NUT
O-ring 
#5148RV
Tip adapter with
retaining nut #7419
2
1
3
6
7
Valve maintenance
To thoroughly clean the fluid body and
replace needle packings:
1. Remove inlet fitting and tip adapter.
2. Remove fluid body from air cylinder body,
then remove O-ring.
3. Use tool #7803 to remove needle
packings from fluid body.
4. Remove any remaining packings and
spring from needle.
5. Clean needle with cloth dampened in
solvent and lubricate with Nye Lubricant
#865 gel included in the General
Maintenance Kit. Lubricate and reinstall
the needle packing assembly.
6. Install new, lubricated O-ring
on fluid body. Then install
chamber into air cylinder
body.
7. Turn the fluid body to posi-
tion fluid inlet hole in the
desired location. Install and
tighten body mounting
screws (2). Torque to 14
inch pounds (1.58 Nm).
8. Reinstall tip adapter/seat
assembly.
Valve Disassembly and
Reassembly Procedures
CAUTION: To prevent damage, the valve
must be disassembled starting at the fluid
outlet end of the valve. 