Cal Flame 2008 Owner’s Manual
 
LTR20081044, Rev. A
Installation / Assembly
As a safety precaution, remember to always leak test 
your  grill  outdoors  in  a  well-ventilated  area.    Never 
smoke or permit sources of ignition in the area while 
doing a leak test.  Do not use a flame, such as a lighted 
match to test for leaks. Use a solution of soapy water.
Prepare a leak testing solution of soapy water by 
1. 
mixing in a spray bottle one part liquid soap to one 
part water.
Make sure all the control knobs are in the OFF po-
2. 
sition.
Turn on the gas. Turn the gas supply valve counter 
3. 
clockwise one turn to open.
Apply  the  leak-testing  solution  by  spraying  it  on 
4. 
joints of the gas delivery system. Blowing bubbles 
in the soap solution indicates that a leak is pres-
ent.
Stop a leak by tightening the loose joint or by re-
5. 
placing the faulty part with a replacement part rec-
ommended by the manufacturer.
Turn  all  control  knobs  back  to  the  full  OFF  posi-
6. 
tion.
If you are unable to stop a leak:
Turn  all  control  knobs  back  to  the  full  OFF  posi-
1. 
tion.
  Shut  off  the  gas  supply  to  the  grill  and  release 
2. 
pressure in the hose and manifold by pushing in 
and turning any of the control valves one quarter 
turn counter-clockwise.
Call  an  authorized  gas  appliance  service  techni-
3. 
cian.
Do not use the appliance until the leak is corrected.
Liquid Propane Gas
Tank Requirements
For plumbed-in LP installation, use a convertible regu-
lator and set it for LP gas. 
Maximum line pressure for plumbed-in propane is 14” 
WC (3.5 kPa). Minimum line pressure for propane is 
11” WC.
Model Number Description
Width
Depth
Height Cut-out for drop in accessories
BBQ08852U
Drop In Standard Side 
Burner
29.2 cm 45.1 cm
7.0 cm
WIDTH
DEPTH
HEIGHT
BBQ08953U
Standard Side by Side 
Burner
61.6 cm 50.2 cm 10.8 cm
BBQ08954U
Deluxe Side by Side 
Burner
64.1 cm
33.7cm 18.4 cm
Leak Testing Procedure
Perform a leak test at least once a year whether the gas supply has been disconnected or not. In addition, whenever 
the gas supply is connected to the regulator or whenever any part of the gas system is disconnected or replaced, 
perform a leak test.