Cal Flame LTR20081044 사용자 설명서

다운로드
페이지 20
Cal Flame 2008 Owner’s Manual 
Page 5
LTR20081044, Rev. A
Installation / Assembly
The grill unit must be used with the gas pressure regula-
tor. The regulator will control and maintain a uniform gas 
pressure in the manifold. The burner orifices have been 
sized for the gas pressure delivered by the regulator.
WARNING: Attempting to operate the grill unit without 
the gas regulator installed could cause an explosion and 
possible death.
LP Gas Hook Up
An enclosure for an LP gas cylinder shall be vented by 
openings at the level of the cylinder valve and at floor 
level. The effectiveness of the openings for purposes of 
ventilation shall be determined with the LP-gas supply 
cylinder in place.  This shall be accomplished in one of 
the following manners:
One  side  of  the  enclosure  shall  be  completely 
1. 
open.
Enclosures that have four sides, complete with a top 
2. 
and bottom:
At  least  two  ventilation  openings  at  cylinder 
a. 
valve  level  shall  be  provided  in  the  sidewall, 
equally  sized,  spaced  at  180º  (3.14  rad),  and 
unobstructed.  Each  opening  shall  have  a  to-
tal  free  area  of  not  less  than  7.1  cm²/kg  (one 
square inch per pound) of stored fuel capacity, 
and not less than a total free area of 64.5 cm² 
(10 square inches).
Ventilation  openings  shall  be  provided  at  floor 
b. 
level and shall have a total free area of not less 
than  7.1  cm²/kg  (one  square  inch  per  pound) 
of stored fuel capacity and not less than a to-
tal free area of 64.5cm² (10 square inches).  If 
ventilation openings at floor level are in a side-
wall, there shall be at least two openings.  The 
bottom  of  the  openings  shall  be  at  floor  level 
and the upper edge no more than 127 mm (5 
inches) above the floor. The openings shall be 
equally sized, spaced at 180º (3.14 rad) and un-
obstructed.
Every opening shall have minimum dimensions 
c. 
so as to permit the entrance of a 3.2 mm (1/8 
inch) diameter rod.
Transporting and Storing LP Gas
Transport only one cylinder at a time. Ensure the cylinder 
is secured in an upright position with the control valve 
turned off and the dust cap in place. Store cylinders out-
doors and out of reach of children. Do not store cylinders 
in a building, garage, or any other enclosed area.
Installing the Transformer
All grills with electrical components such as lights or a 
convection fan will require the transformer to be installed 
and plugged in before you can use it. This needs to be 
done before the grill is inserted in the barbecue island. 
When  the  transformer  is  attached  to  the  grill  chassis, 
use care in placing the grill in the island cutout to avoid 
hitting the transformer.