OPERATION
OTE:
N
If the engine fails to start after 5 seconds, 
release the engine control switch. Let the 
generator sit idle for 15 seconds and then 
repeat step 5. If the cranking speed drops 
after each unsuccessful attempt, then the 
battery may not be adequately charged. 
Manually start the generator as instructed 
in Manually Starting a Generator on page 
22
.
OTE:
N
The electric start generator is equipped 
with a battery charging feature. Once 
the engine is running, a small charge is 
supplied to the battery via the battery 
cables and will slowly recharge the battery. 
6.  As the engine starts and stabilizes, gradually move 
the choke lever back to the OFF position.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to stop 
your generator:
1.  Remove any connected loads from the control 
panel receptacles.
2.  Allow the generator to run at “no load” to reduce 
and stabilize engine and alternator temperatures.
3.  Push the engine control switch to the OFF position.
4.  Turn the fuel shutoff valve to the OFF position.
During an Emergency
If there is an emergency and the generator must be 
stopped quickly, push the engine control switch to the 
OFF position immediately.