9.  Dry the air filter elements by again applying a slow 
firm squeezing action.
10.  Once the air filters are dry, coat the air filters with 
clean engine oil (see Figure 31).
Figure 31
11.  Squeeze the filters to remove any excess oil (see 
Figure 32).
Figure 32
12.  Install the gray fine inside air filter into the air filter 
housing first.
13.  Install the black coarse outside air filter on top of 
the fine filter.
14.  Install the air filter cover by clipping the clips on the 
top and bottom of the air filter assembly (see Figure 
33)
.
Figure 33 – Installation of Air Filter Cover
SPARK PLUG MAINTENANCE
The spark plug must be checked and cleaned after 
every 100 hours of use or 6 months and must be 
replaced after 300 hours of use or every year.
1.  Stop the generator and let it cool for several 
minutes if running.
2.  Move the generator to a flat, level surface.
3.  Remove the spark plug boot by firmly pulling the 
plastic spark plug boot handle directly away from 
the engine (see Figure 34).
NOTICE
Never apply any side load or move the spark plug 
laterally when removing the spark plug. Applying a 
side load or moving the spark plug laterally may crack 
and damage the spark plug boot.