Westinghouse CSA (Canada) WHC6000S CSA MODEL 사용자 매뉴얼

다운로드
페이지 76
32 
MAINTENANCE
CLEANING THE SPARK 
ARRESTOR
Check and clean the spark arrestor after every 100 
hours of use or 6 months. 
1.  Stop the generator and let it cool for several 
minutes if running.
2.  Move the generator to a flat, level surface.
3.  Using a flathead screwdriver, loosen the spark 
arrestor band clamp (see Figure 37).
3
1
2
Figure 37 – Spark Arrestor Assembly
1 -  Spark Arrestor 
 Band 
Clamp
2 -  Spark Arrestor 
 Screen
3 -  Muffler
4.  Slide the spark arrestor band clamp off the spark 
arrestor screen.
5.  Pull the spark arrestor screen off the muffler 
exhaust pipe.
6.  Using a wire brush, remove any dirt and debris that 
may have collected on the spark arrestor screen.
7.  If the spark arrestor screen shows signs of wear 
(rips, tears or large openings in the screen), replace 
the spark arrestor screen.
8.  Install the spark arrestor components in the 
following order:
a -  
Place spark arrestor screen over the muffler 
exhaust pipe. Push on the screen until it fully 
bottoms out.
b -  
Place the spark arrestor band clamp over the 
screen and tighten with a flathead screwdriver.
CLEANING THE GENERATOR
It is important to inspect and clean the generator before 
every use.
Clean All Engine Air Inlet and Outlet Ports – Make 
sure all engine air inlet and outlet ports are clean of any 
dirt and debris to ensure the engine does not run hot 
(see Figure 38).
Figure 38 – Engine Air Inlet and Outlet Ports
Clean All Engine Cooling Fins – Use a damp rag and 
a brush to loosen and remove all dirt on or around the 
engine’s cooling fins (see Figure 39).