MAINTENANCE
Clean All Alternator Cooling Air Inlets and Exhaust 
Ports –
 Make sure the cooling air inlets and exhaust 
ports of the alternator are free of any debris and 
obstructions. Use a vacuum cleaner to remove dirt and 
debris stuck in the cooling air inlets and exhaust ports 
(see Figure 40 and Figure 41).
Figure 40 – Alternator Cooling Air Inlet and Outlet Port
Figure 41 – Alternator Cooling Air Inlet and Outlet Port
General Cleaning of the Generator – Use a damp rag 
to clean all remaining surfaces.
BATTERY SERVICE
To ensure the battery remains charged, the generator 
should be started every 2 to 3 months and run for a 
minimum of 15 minutes. If the generator is stored more 
than a year without running, a battery charger may be 
needed to recharge the battery. 
Battery Replacement
1.  Remove the spark plug wire from spark plug.
2.  Loosen and remove the nuts on the battery hold-
down plate and remove the plate from the support 
rods (see Figure 42).
1
2
3
Figure 42
1 -  Nuts
2 -   Battery Hold- 
Down Plate
3 -  Support Rods 
3.  Tip the battery forward slightly to access battery 
cables.
4.  Disconnect the black negative (-) battery cable from 
the battery first.
5.  Disconnect the red positive (+) battery cable 
second and remove the battery.