8.3.6  LOST ENTRY CODE 
If the Entry code is misplaced it will be necessary to 
ENTER
 the 
"CALIB/CHANGE"
 activity and delete all codes 
as described above.  To enter the 
"CALIB/CHANGE"
 
activity: 
1.  Turn Sentry off and then on to start the warm-
up.   
2.  Press 
RESET
 key three times to 
"RESET 
HISTORY"
   
3.  Press 
ENTER
 to display 
"USE ARROWS/ENTER" 
"ENTRY CODE=0"
 
4.  Press 
TEST
 key  
THREE
  times.  No changes will 
be apparent. 
5.  Enter the entry code: 9999. 
6.  The 
"CALIB/CHANGE"
 light will turn on and the 
"SET USER CODE"
 activity can be selected so 
that the entry code can be changed.