GE SX TRANSISTOR CONTROL IC3645SR4U404N2 사용자 설명서

다운로드
페이지 74
DIAGNOSTIC STATUS CODES  
SX TRANSISTOR CONTROL 
 
 
Page 44
 
 
 
January 2000
 
 
TRACTION 
STATUS CODE
 
DESCRIPTION OF STATUS 
CAUSE OF STATUS INDICATION 
-95 
Pump motor brush wear indicator has 
detected worn brush.
 
This status code will be displayed when the voltage at 
the respective terminal of the TMM or Pump Logic 
Card is at battery volts.
 
MEMORY RECALL  
YES
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump  
Motor 
Brush Wear 
Indicator 
 
 
 
SYMPTOM 
Status code flashes “on and off”. 
 
POSSIBLE CAUSE 
User defined status code is displayed by motor 
brush sensor closure to battery positive. 
 
Plug P8 (pump) is shorted to positive. 
 
Defective input switch (shorted). 
 
Defective TMM card. 
 
Defective pump card.
 
SC95
POS
P8
USER SW
WHEN SR Series PUMP
CONTROL IS USED
 
 
TRACTION 
STATUS CODE
 
DESCRIPTION OF STATUS 
CAUSE OF STATUS INDICATION 
-95 
Pump motor brush wear indicator has 
detected worn brush.
 
This status code will be displayed when the voltage at 
the respective terminal of the TMM or Pump Logic 
Card is at battery volts.
 
MEMORY RECALL  
YES
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump  
Motor 
Brush Wear 
Indicator 
 
 
 
SYMPTOM 
Status code flashes “on and off”. 
 
POSSIBLE CAUSE 
User defined status code is displayed by motor 
brush sensor closure to battery positive. 
 
Plug P9 (pump) is shorted to positive. 
 
Defective input switch (shorted). 
 
Defective TMM card. 
 
Defective pump card.
 
SC95A
POS
P9
USER SW
WHEN SR Series PUMP
CONTROL IS USED