GE SX TRANSISTOR CONTROL IC3645SR4U404N2 사용자 설명서

다운로드
페이지 74
DIAGNOSTIC STATUS CODES  
SX TRANSISTOR CONTROL 
 
 
Page 45
 
 
 
January 2000
 
 
TRACTION 
STATUS CODE
 
DESCRIPTION OF STATUS 
CAUSE OF STATUS INDICATION 
-99 
Maintenance alert and speed limit.
 
This status code will be displayed when the “normal” 
hour meter exceeds the “maintenance alert hours” 
setting for the vehicle.
 
MEMORY RECALL  
YES
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Traction 
Controller 
 
 
 
 
 
 
 
SYMPTOM 
Status code is displayed for 4 seconds when the 
key switch is first turned on, and/or the vehicle 
may run at a reduced speed. 
 
CUSTOMER SELECTED SETTING WITH THE 
HANDSET:
 
User defined status code is displayed when the 
normal hour meter reading exceeds the 
programmed “maintenance alert hours” setting 
selected by the user 
= Maintenance Code Hour Meter, Functions 19 
and 20, are programmed with the Handset and 
command the display of status code -99. 
= If desired, Maintenance Code Speed Limit, 
Function 13, can be programmed with the 
Handset. 
 
User should perform the desired maintenance 
function. Re-set maintenance alert hour meter 
after maintenance is performed.  
 
 
NO DIAGRAM 
 
USER SHOULD PERFORM THE DESIRED 
MAINTENANCE FUNCTION