DIAGNOSTIC STATUS CODES 
TRANSISTOR PUMP CONTROL 
 
 
Page  48 
January 2000
 
 
 
PUMP   
STATUS CODE
 
DESCRIPTION OF 
STATUS
 
CAUSE OF STATUS INDICATION
 
-142 
Pump Controller “motor current 
sensor” input is missing. 
This status code is displayed when the voltage at the 
current sensor is greater than 0.1 volts with no current 
flowing in the motor circuit. 
MEMORY RECALL  
NO
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
 
SYMPTOM 
No power to pump motor in 
control range.  
 
POSSIBLE CAUSE 
Control is defective. 
=Replace controller unit. 
 
 
POWER
CONNECTIONS
POS
A1
NEG
A2
FI
EL
D
ARMATURE
+
-
FU1
FU3
KEY SWITCH
P1
P2
P3
P12
LINE
FU6
P19
P21
TO
TRACTION
CARD
SPEED L
IMI
T 1
SPEED L
IMI
T 2
SPEED L
IMI
T 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11
 
 
PUMP   
STATUS CODE
 
DESCRIPTION OF STATUS
 
CAUSE OF STATUS INDICATION
 
-143 
Pump Controller “motor current 
sensor” input is too low. 
This status code is displayed when the voltage at the 
current sensor is greater than 0.1 volts with no current 
flowing in the motor circuit. 
MEMORY RECALL  
NO
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
 
SYMPTOM 
No power to pump motor in 
control range.  
 
POSSIBLE CAUSE 
Control is defective. 
=Replace controller unit. 
 
 
 
POWER
CONNECTIONS
POS
A1
NEG
A2
FI
EL
D
ARMATURE
+
-
FU1
FU3
KEY SWITCH
P1
P2
P3
P12
LINE
FU6
P19
P21
TO
TRACTION
CARD
SPEED L
IMI
T 1
SPEED L
IMI
T 2
SPEED L
IMI
T 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11