GE SX TRANSISTOR CONTROL IC3645SR4U404N2 사용자 설명서

다운로드
페이지 74
DIAGNOSTIC STATUS CODES 
TRANSISTOR PUMP CONTROL 
 
 
Page  47 
January 2000
 
 
 
PUMP   
STATUS CODE
 
DESCRIPTION OF STATUS
 
CAUSE OF STATUS INDICATION
 
-128 
Armature current is too high during the 
lift mode. 
Status code displayed when the current in the 
armature circuit is sustained above 300A for 70 sec. 
MEMORY RECALL  
YES
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
 
SYMPTOM 
Control will not operate. 
  
POSSIBLE CAUSE 
Continued operation of vehicle in high 
motor current condition. 
=
Operate vehicle at lower motor current 
condition for 70 seconds.
 
FU3
KEY SWITCH
P1 P2
FU2
POWER CONNECTIONS
POS
A1
NEG
A2
FIE
L
D
ARM
A
T
URE
+
-
FU1
LINE
 
 
 
PUMP   
STATUS CODE
 
DESCRIPTION OF 
STATUS
 
CAUSE OF STATUS INDICATION
 
-141 
Open thermal protector (TP1) or 
transistor is over temperature. 
This status code is displayed when the voltage at the thermal 
protector is greater than 0.8 volts. 
MEMORY RECALL  
NO
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
 
SYMPTOM 
Reduced or no power to pump motor in 
control range. 
 
POSSIBLE CAUSE 
 
Control is in thermal cut-back. 
= Allow control to cool, status code 
should disappear. 
POWER
CONNECTIONS
POS
A1
NEG
A2
FI
EL
D
ARMATURE
+
-
FU1
FU3
KEY SWITCH
P1
P2
P3
P12
LINE
FU6
P19
P21
TO
TRACTION
CARD
SPEED L
IMI
T 1
SPEED L
IMI
T 2
SPEED L
IMI
T 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11